A Method of Estimating the Stability of the Scale Factor of a Transmission Electron Microscope

A method of estimating the stability of the scale factor of the JEM-2100 transmission electron microscope using a test-object, constructed in the form of a thin section of a crystalline relief nanostructure with a known shape of the profile, is proposed. The results of an experimental estimate, obta...

Full description

Saved in:
Bibliographic Details
Published inMeasurement techniques Vol. 56; no. 5; pp. 482 - 485
Main Authors Zablotskii, A. V., Avilov, A. S., Bodunov, D. S., Kuzin, A. A., Kuzin, A. Yu, Kuz’min, A. A., Todua, P. A.
Format Journal Article
LanguageEnglish
Published Boston Springer US 01.08.2013
Springer
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A method of estimating the stability of the scale factor of the JEM-2100 transmission electron microscope using a test-object, constructed in the form of a thin section of a crystalline relief nanostructure with a known shape of the profile, is proposed. The results of an experimental estimate, obtained over a two-week period, are presented.