Diffuse lung disease: assessment with helical CT--preliminary observations of the role of maximum and minimum intensity projection images

To evaluate assessment of diffuse lung disease with helical computed tomography (CT) and maximum intensity projection (MIP) and minimum intensity projection images. Six patients with suspected lung disease (the control group) and 20 patients with documented disease underwent axial helical CT through...

Full description

Saved in:
Bibliographic Details
Published inRadiology Vol. 200; no. 2; p. 341
Main Authors Bhalla, M, Naidich, D P, McGuinness, G, Gruden, J F, Leitman, B S, McCauley, D I
Format Journal Article
LanguageEnglish
Published United States 01.08.1996
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:To evaluate assessment of diffuse lung disease with helical computed tomography (CT) and maximum intensity projection (MIP) and minimum intensity projection images. Six patients with suspected lung disease (the control group) and 20 patients with documented disease underwent axial helical CT through the upper and lower lung fields. Findings on the MIP and minimum intensity projection images of each helical data set were compared with findings on the thin-section scan obtained at the midplane of the series. Owing to markedly improved visualization of peripheral pulmonary vessels (n = 26) and improved spatial orientation, MIP images were superior to helical scans to help identify pulmonary nodules and characterize them as peribronchovascular (n = 2) or centrilobular (n = 7). Minimum intensity projection images were more accurate than thin-section scans to help identify lumina of central airways (n = 23) and define abnormal low (n = 15) and high (ground-glass) (n = 8) lung attenuation. Conventional thin-section scans depicted fine linear structures more clearly than either MIP or minimum intensity projection images, including the walls of peripheral, dilated airways (n = 3) and interlobular septa (n = 3). MIP and minimum intensity projection images added additional diagnostic findings to those on thin-section scans in 13 (65%) of 20 cases. MIP and minimum intensity projection images of helical data sets may help diagnosis of a wide spectrum of diffuse lung diseases.
ISSN:0033-8419
DOI:10.1148/radiology.200.2.8685323