Biomechanical evaluation of stability and three-dimensional movements of the atlantoaxial joint after artificial atlanto-odontoid joint arthroplasty

Objective:  To investigate the stability and three‐dimensional movements of the atlantoaxial joint after artificial atlanto‐odontoid joint (AAOJ) arthroplasty. Method:  Ten sets of AAOJ implanted in bony specimens from 10 adults were used to test the pull‐out strength of the atlas‐axis components wi...

Full description

Saved in:
Bibliographic Details
Published inOrthopaedic surgery Vol. 2; no. 2; pp. 111 - 118
Main Authors Hu, Yong, Gu, Yong-jie, He, Xian-feng, Xu, Rong-ming, Ma, Wei-hu, Zhao, Wei-dong, Liang, Dong-zhu, Zhong, Shi-zhen
Format Journal Article
LanguageEnglish
Published Melbourne, Australia Blackwell Publishing Asia 01.05.2010
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective:  To investigate the stability and three‐dimensional movements of the atlantoaxial joint after artificial atlanto‐odontoid joint (AAOJ) arthroplasty. Method:  Ten sets of AAOJ implanted in bony specimens from 10 adults were used to test the pull‐out strength of the atlas‐axis components with a MTS858 Mini Bionix machine. Another twelve human cadaveric specimens including C0‐C4 were used to evaluate the three‐dimensional movements of C1‐C2 under five different conditions in sequence, that is, the complete specimen, anterior decompression, posterior transarticular screws fixation, AAOJ arthroplasty and fatigue test. Result:  There were significant differences between atlas and axis components in the maximum pull‐out strength and trajectory length, however the yield length was not significantly different. The maximum pull‐out strength of the atlas and axis was positively correlated with trajectory length (r1= 0.880, P < 0.05) and yield length (r2= 0.606, P < 0.05), respectively. After AAOJ arthroplasty, the range of movement (ROM) with respect to rotation and the neutral zone of the atlantoaxial joint were close to normal (P > 0.05), but the ROM in flexion‐extension and lateral bending was significantly smaller compared with the specimens which underwent anterior decompression (P < 0.05). No abrasion and abnormal mobilization were observed after 2000 cycles of flexion, extension, lateral bending and axial rotation in the fatigue test. Conclusions:  The self‐designed AAOJ has excellent biomechanical performance, and AAOJ arthroplasty can restore excellent instant stability and preserve the movement of the atlantoaxial joint.
Bibliography:ArticleID:OS73
istex:4929120813935C5AD20903FA0A6D6F877CA05447
ark:/67375/WNG-GQZGMMZ3-H
ISSN:1757-7853
1757-7861
DOI:10.1111/j.1757-7861.2010.00073.x