Effects of nanostructuration on the electrochemical performance of metallic bioelectrodes
The use of metallic nanostructures in the fabrication of bioelectrodes ( e.g. , neural implants) is gaining attention nowadays. Nanostructures provide increased surface area that might benefit the performance of bioelectrodes. However, there is a need for comprehensive studies that assess electroche...
Saved in:
Published in | Nanoscale Vol. 14; no. 8; pp. 3179 - 319 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
England
Royal Society of Chemistry
24.02.2022
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The use of metallic nanostructures in the fabrication of bioelectrodes (
e.g.
, neural implants) is gaining attention nowadays. Nanostructures provide increased surface area that might benefit the performance of bioelectrodes. However, there is a need for comprehensive studies that assess electrochemical performance of nanostructured surfaces in physiological and relevant working conditions. Here, we introduce a versatile scalable fabrication method based on magnetron sputtering to develop analogous metallic nanocolumnar structures (NCs) and thin films (TFs) from Ti, Au, and Pt. We show that NCs contribute significantly to reduce the impedance of metallic surfaces. Charge storage capacity of Pt NCs is remarkably higher than that of Pt TFs and that of the other metals in both morphologies. Circuit simulations of the electrode/electrolyte interface show that the signal delivered in voltage-controlled systems is less filtered when nanocolumns are used. In a current-controlled system, simulation shows that NCs provide safer stimulation conditions compared to TFs. We have assessed the durability of NCs and TFs for potential use
in vivo
by reactive accelerated aging test, mimicking one-year
in vivo
implantation. Although each metal/morphology reveals a unique response to aging, NCs show overall more stable electrochemical properties compared to TFs in spite of their porous structure.
Nanostructuration of metallic films improves their electrical impedance and charge storage capacity. It provides a wider biologically safe operation voltage range and accurate signal transfer. Au and Pt nanocolumns are resilient to oxidative aging. |
---|---|
Bibliography: | vs. 10.1039/d1nr06280h 2 decay plot; impedance statistics; current sweep rate plots; AFM images and RMS data; transient electrical simulation for Ti and Au; Raman spectra for Ti TFs; EDX characterizations after aging; equivalent circuits for Au NCs and TFs. See DOI Electronic supplementary information (ESI) available: Schematics of experimental setups; H O ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 2040-3364 2040-3372 |
DOI: | 10.1039/d1nr06280h |