Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial

A new carrier-bound fibrin sealant, TachoSil, is expected to be efficacious and safe as a haemostatic treatment in hepatic resection. A prospective, randomised, open and controlled multicentre trial with intraoperative as well as postoperative assessment of efficacy and a 1 month follow-up period. T...

Full description

Saved in:
Bibliographic Details
Published inLangenbeck's archives of surgery Vol. 390; no. 2; pp. 114 - 120
Main Authors Frilling, Andrea, Stavrou, Gregor A, Mischinger, Hans-Jörg, de Hemptinne, Bernard, Rokkjaer, Mogens, Klempnauer, Jürgen, Thörne, Anders, Gloor, Beat, Beckebaum, Susanne, Ghaffar, Mohamed F A, Broelsch, Christoph E
Format Journal Article
LanguageEnglish
Published Germany 01.04.2005
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A new carrier-bound fibrin sealant, TachoSil, is expected to be efficacious and safe as a haemostatic treatment in hepatic resection. A prospective, randomised, open and controlled multicentre trial with intraoperative as well as postoperative assessment of efficacy and a 1 month follow-up period. Tertiary care centres. One hundred and twenty-one patients requiring secondary haemostasis during planned liver resection. Patients with coagulation disorders and patients with persistent major bleeding after primary haemostatic measures were excluded. Application of either carrier-bound fibrin sealant (n=59) or argon beamer (argon beam coagulator) (n=62) as secondary haemostatic treatment. Time to intraoperative haemostasis. There was a significant superiority of TachoSil over argon beamer with regard to time to haemostasis (3.9 min, median 3.0, range 3-20 min vs 6.3 min, median 4.0, range 3-39 min) (P=0.0007). Haemoglobin concentration of drainage fluid was significantly lower on day 2 after surgery in TachoSil patients (1.1 mmol/l) than in argon beamer patients (2.3 mmol/l) (P=0.012). Overall, the frequency and causality of adverse events did not differ between the two treatment groups. TachoSil is superior to argon beamer in obtaining effective and fast intraoperative haemostasis. The safety data show TachoSil to be tolerable and safe for haemostatic treatment in liver resection.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-News-2
ObjectType-Feature-3
content type line 23
ISSN:1435-2443
1435-2451