The effect of change in flow rate on the vibration of double-suction centrifugal pumps

Abstract This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that wil...

Full description

Saved in:
Bibliographic Details
Published inProceedings of the Institution of Mechanical Engineers. Part E, Journal of process mechanical engineering Vol. 216; no. 1; pp. 47 - 58
Main Authors Hodkiewicz, M R, Norton, M P
Format Journal Article
LanguageEnglish
Published London, England SAGE Publications 01.01.2002
Mechanical Engineering Publications
SAGE PUBLICATIONS, INC
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that will assist in identifying low flow conditions in double-suction pumps.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0954-4089
2041-3009
DOI:10.1243/095440802760075030