The effect of change in flow rate on the vibration of double-suction centrifugal pumps
Abstract This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that wil...
Saved in:
Published in | Proceedings of the Institution of Mechanical Engineers. Part E, Journal of process mechanical engineering Vol. 216; no. 1; pp. 47 - 58 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
London, England
SAGE Publications
01.01.2002
Mechanical Engineering Publications SAGE PUBLICATIONS, INC |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Abstract
This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that will assist in identifying low flow conditions in double-suction pumps. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 0954-4089 2041-3009 |
DOI: | 10.1243/095440802760075030 |