Use of a Noise Optimized Monoenergetic Algorithm for Patient-Size Independent Selection of an Optimal Energy Level During Dual-Energy CT of the Pancreas
To investigate the impact of a second-generation noise-optimized monoenergetic algorithm on selection of the optimal energy level, image quality, and effect of patient body habitus for dual-energy multidetector computed tomography of the pancreas. Fifty-nine patients (38 men, 21 women) underwent dua...
Saved in:
Published in | Journal of computer assisted tomography Vol. 41; no. 1; p. 39 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.01.2017
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Summary: | To investigate the impact of a second-generation noise-optimized monoenergetic algorithm on selection of the optimal energy level, image quality, and effect of patient body habitus for dual-energy multidetector computed tomography of the pancreas.
Fifty-nine patients (38 men, 21 women) underwent dual-energy multidetector computed tomography (80/Sn140 kV) in the pancreatic parenchymal phase. Image data sets, at energy levels ranging from 40 to 80 keV (in 5-keV increments), were reconstructed using first-generation and second-generation noise-optimized monoenergetic algorithm. Noise, pancreatic contrast-to-noise ratio (CNRpancreas), and CNR with a noise constraint (CNRNC) were calculated and compared among the different reconstructed data sets. Qualitative assessment of image quality was performed by 3 readers.
For all energy levels below 70 keV, noise was significantly lower (P ≤ 0.05) and CNRpancreas significantly higher (P < 0.001), with the second-generation monoenergetic algorithm. Furthermore, the second-generation algorithm was less susceptible to variability related to patient body habitus in the selection of the optimal energy level. The maximal CNRpancreas occurred at 40 keV in 98% (58 of 59) of patients with the second-generation monoenergetic algorithm. However, the CNRNC and readers' image quality scores showed that, even with a second-generation monoenergetic algorithm, higher reconstructed energy levels (60-65 keV) represented the optimal energy level.
Second-generation noise-optimized monoenergetic algorithm can improve the image quality of lower-energy monoenergetic images of the pancreas, while decreasing the variability related to patient body habitus in selection of the optimal energy level. |
---|---|
ISSN: | 1532-3145 |
DOI: | 10.1097/rct.0000000000000492 |