Use of a Noise Optimized Monoenergetic Algorithm for Patient-Size Independent Selection of an Optimal Energy Level During Dual-Energy CT of the Pancreas

To investigate the impact of a second-generation noise-optimized monoenergetic algorithm on selection of the optimal energy level, image quality, and effect of patient body habitus for dual-energy multidetector computed tomography of the pancreas. Fifty-nine patients (38 men, 21 women) underwent dua...

Full description

Saved in:
Bibliographic Details
Published inJournal of computer assisted tomography Vol. 41; no. 1; p. 39
Main Authors Bellini, Davide, Gupta, Sonia, Ramirez-Giraldo, Juan Carlos, Fu, Wanyi, Stinnett, Sandra S, Patel, Bhavik, Mileto, Achille, Marin, Daniele
Format Journal Article
LanguageEnglish
Published United States 01.01.2017
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:To investigate the impact of a second-generation noise-optimized monoenergetic algorithm on selection of the optimal energy level, image quality, and effect of patient body habitus for dual-energy multidetector computed tomography of the pancreas. Fifty-nine patients (38 men, 21 women) underwent dual-energy multidetector computed tomography (80/Sn140 kV) in the pancreatic parenchymal phase. Image data sets, at energy levels ranging from 40 to 80 keV (in 5-keV increments), were reconstructed using first-generation and second-generation noise-optimized monoenergetic algorithm. Noise, pancreatic contrast-to-noise ratio (CNRpancreas), and CNR with a noise constraint (CNRNC) were calculated and compared among the different reconstructed data sets. Qualitative assessment of image quality was performed by 3 readers. For all energy levels below 70 keV, noise was significantly lower (P ≤ 0.05) and CNRpancreas significantly higher (P < 0.001), with the second-generation monoenergetic algorithm. Furthermore, the second-generation algorithm was less susceptible to variability related to patient body habitus in the selection of the optimal energy level. The maximal CNRpancreas occurred at 40 keV in 98% (58 of 59) of patients with the second-generation monoenergetic algorithm. However, the CNRNC and readers' image quality scores showed that, even with a second-generation monoenergetic algorithm, higher reconstructed energy levels (60-65 keV) represented the optimal energy level. Second-generation noise-optimized monoenergetic algorithm can improve the image quality of lower-energy monoenergetic images of the pancreas, while decreasing the variability related to patient body habitus in selection of the optimal energy level.
ISSN:1532-3145
DOI:10.1097/rct.0000000000000492