The performance of a low-cost bio-amplifier on 3D human arm movement reconstruction

Objectives In this study, the performance of OpenBCI, a low-cost bio-amplifier, is assessed when used for 3D motion reconstruction. Methods Eleven scalp electrode locations from three subjects were used, with sampling rate of 125 Hz, subsequently band-pass filtered from 0.5 to 40 Hz. After segmentat...

Full description

Saved in:
Bibliographic Details
Published inBiomedizinische Technik Vol. 65; no. 5; pp. 577 - 585
Main Authors Ayodele, Kayode P., Akinboboye, Eniola A., Komolafe, Morenikeji A.
Format Journal Article
LanguageEnglish
Published Germany De Gruyter 25.10.2020
Walter de Gruyter GmbH
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives In this study, the performance of OpenBCI, a low-cost bio-amplifier, is assessed when used for 3D motion reconstruction. Methods Eleven scalp electrode locations from three subjects were used, with sampling rate of 125 Hz, subsequently band-pass filtered from 0.5 to 40 Hz. After segmentation into epochs, information-rich frequency ranges were determined using filter bank common spatial filter. Simultaneously, the actual hand motions of subjects were captured using a Microsoft Kinect sensor. Multimodal data streams were synchronized using the lab streaming layer (LSL) application. A modified version of an existing multiple linear regression models was employed to learn the relationship between the electroencephalography (EEG) feature input and the recorded kinematic data. To assess system performance with limited data, 10-fold cross validation was used. Results The most information-rich frequency bands for subjects were found to be in the ranges of 5 - 9 Hz and 33 - 37 Hz. Hand lateralization accuracy for the three subjects were 97.4, 78.7 and 96.9% respectively. 3D position reconstructed with an average correlation coefficient of 0.21, 0.47 and 0.38 respectively along three pre-defined axes, with the corresponding average correlation coefficients for velocity being 0.21, 0.36 and 0.25 respectively. The results compare favourably with a cross-section of existing results, while cost-per-electrode costs were 76% lower than the average per-electrode cost for similar systems and 44% lower than the cheapest previously-reported system. Conclusions This study has shown that low-cost bio-amplifiers such as the OpenBCI can be used for 3D motion reconstruction tasks.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0013-5585
1862-278X
1862-278X
DOI:10.1515/bmt-2019-0085