Exhaled patient derived aerosol dispersion during awake tracheal intubation with concurrent high flow nasal therapy

Awake Tracheal Intubation (ATI) can be performed in cases where there is potential for difficult airway management. It is considered an aerosol generating procedure and is a source of concern to healthcare workers due to the risk of transmission of airborne viral infections, such as SARS–CoV-2. At p...

Full description

Saved in:
Bibliographic Details
Published inJournal of clinical monitoring and computing Vol. 37; no. 5; pp. 1265 - 1273
Main Authors Eain, Marc Mac Giolla, Nolan, Kevin, Murphy, Brian, McCaul, Conan, MacLoughlin, Ronan
Format Journal Article
LanguageEnglish
Published Dordrecht Springer Netherlands 01.10.2023
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Awake Tracheal Intubation (ATI) can be performed in cases where there is potential for difficult airway management. It is considered an aerosol generating procedure and is a source of concern to healthcare workers due to the risk of transmission of airborne viral infections, such as SARS–CoV-2. At present, there is a lack of data on the quantities, size distributions and spread of aerosol particles generated during such procedures. This was a volunteer observational study which took place in an operating room of a university teaching hospital. Optical particle sizers were used to provide real time aerosol characterisation during a simulated ATI performed with concurrent high-flow nasal oxygen therapy. The particle sizers were positioned at locations that represented the different locations of clinical staff in an operating room during an ATI. The greatest concentration of patient derived aerosol particles was within 0.5–1.0 m of the subject and along their midline, 2242 #/cm 3 . As the distance, both radial and longitudinal, from the subject increased, the concentration decreased towards ambient levels, 36.9 ± 5.1 #/cm 3 . Patient derived aerosol particles < 5 µm in diameter remained entrained in the exhaled aerosol plume and fell to the floor or onto the subject. Patient derived particles > 5 µm in diameter broke away from the exhaled plume and spread radially throughout the operating room. Irrespective of distance and ventilation status, full airborne protective equipment should be worn by all staff when ATI is being performed on patients with suspected viral respiratory infections.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:1387-1307
1573-2614
1573-2614
DOI:10.1007/s10877-023-00990-x