Laboratory Investigation of Vapor Shielding for Lithium-Coated Molybdenum in Devex

To investigate the effect of lithium on a molybdenum target, a triple Langmuir probe diagnostics and target temperature measurements are carried out. Several experimental scenarios are tested to optimize the device for the vapor shielding experiment. A lithium sputtering system is used to deposit li...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on plasma science Vol. 40; no. 3; pp. 730 - 734
Main Authors Soonwook Jung, Andruczyk, D., Ruzic, D. N.
Format Journal Article
LanguageEnglish
Published New York IEEE 01.03.2012
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To investigate the effect of lithium on a molybdenum target, a triple Langmuir probe diagnostics and target temperature measurements are carried out. Several experimental scenarios are tested to optimize the device for the vapor shielding experiment. A lithium sputtering system is used to deposit lithium on a molybdenum target. A triple Langmuir probe is placed near the target at various pressures to estimate change of plasma density and electron temperature and their effects on vapor shielding. Temperature increase at the target is measured by a thermocouple and its relationship with plasma parameters and lithium is discussed in detail.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0093-3813
1939-9375
DOI:10.1109/TPS.2011.2181980