Determination of seven selected neuro- and immunomodulatory steroids in human cerebrospinal fluid and plasma using LC-MS/MS

•LC–MS/MS method employing 2-hydrazinopyridine derivatization was developed/validated.•For the first time the determination of 7-oxo-DHEA in CSF was reported.•Plasma and CSF cortisol, cortisone, DHEA, 7α/7β/16α-OH-/7-oxo-DHEA were quantified.•Method enables the complex evaluation of 11β-hydroxystero...

Full description

Saved in:
Bibliographic Details
Published inSteroids Vol. 98; pp. 1 - 8
Main Authors Sosvorova, Lucie, Vitku, Jana, Chlupacova, Tereza, Mohapl, Milan, Hampl, Richard
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.06.2015
Subjects
Online AccessGet full text
ISSN0039-128X
1878-5867
1878-5867
DOI10.1016/j.steroids.2015.01.019

Cover

More Information
Summary:•LC–MS/MS method employing 2-hydrazinopyridine derivatization was developed/validated.•For the first time the determination of 7-oxo-DHEA in CSF was reported.•Plasma and CSF cortisol, cortisone, DHEA, 7α/7β/16α-OH-/7-oxo-DHEA were quantified.•Method enables the complex evaluation of 11β-hydroxysteroid dehydrogenase activity. Dehydroepiandrosterone (DHEA) and its 7-oxo- and 7-hydroxy-metabolites occurring in the brain are considered neurosteroids. Metabolism of the latter is catalysed by 11β-hydroxysteroid dehydrogenase (11β-HSD) which also interconverts cortisol and cortisone. The concurrent metabolic reaction to DHEA 7-hydroxylation is the formation of 16α-hydroxy-DHEA. The LC–MS/MS method using triple stage quadrupole-mass spectrometer was developed for simultaneous quantification of free DHEA, 7α-hydroxy-DHEA, 7β-hydroxy-DHEA, 7-oxo-DHEA, 16α-hydroxy-DHEA, cortisol and cortisone in human plasma and cerebrospinal fluid (CSF). The method employs 500μL of human plasma and 3000μL of CSF extracted with diethyl ether and derivatized with 2-hydrazinopyridine. It has been validated in terms of sensitivity, precision and recovery. In plasma, the following values were obtained: limit of detection: 2–50pg/mL; limit of quantification: 5–140pg/mL; within-day precision 0.58–14.58%; between-day precision: 1.24–13.89% and recovery: 85–113.2%). For CSF, the values of limit of detection: 2–28pg/mL; limit of quantification: 6–94pg/mL; within-day precision; 0.63–5.48%; between-day precision: 0.88–14.59% and recovery: 85.1–109.4% were acquired. Medians and concentration ranges of detected steroids in plasma and CSF are given in subjects with excluded normal pressure hydrocephalus (n=37; 65–80years). The method enables simultaneous quantification of steroids important for the estimation of 11β-HSD activity in human plasma and CSF. It will be helpful in better understanding various degenerative diseases development and progression.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0039-128X
1878-5867
1878-5867
DOI:10.1016/j.steroids.2015.01.019