Densities and Viscosities of 1-butyl-3-methylimidazolium Hexafluorophosphate [bmim][PF6] + CO2 Binary System: Determination and Correlation
A gas-dissolving device was designed and connected to the falling-body viscometer, which was used to determine the viscosities of liquids in our lab before. The equipment can be used to determine the gas composition, the densities and viscosities of the solution at the same time. The densities and v...
Saved in:
Published in | Chinese journal of chemical engineering Vol. 21; no. 11; pp. 1284 - 1290 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
Elsevier B.V
01.11.2013
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A gas-dissolving device was designed and connected to the falling-body viscometer, which was used to determine the viscosities of liquids in our lab before. The equipment can be used to determine the gas composition, the densities and viscosities of the solution at the same time. The densities and viscosities of [bmim][PF6] + CO2 binary system were determined in the temperature range of 313.2 to 413.2 K and pressure range of 5.0 to 25.0 MPa by the equipment. Then the viscosities of [bmim][PF6] + CO2 binary system at constant temperature, constant pressure, and different temperature and pressure were correlated, respectively. For the correlation at different tempera- ture and different t3ressure for different concentration mixtures the average relative deviation ARD is 0.037. |
---|---|
Bibliography: | A gas-dissolving device was designed and connected to the falling-body viscometer, which was used to determine the viscosities of liquids in our lab before. The equipment can be used to determine the gas composition, the densities and viscosities of the solution at the same time. The densities and viscosities of [bmim][PF6] + CO2 binary system were determined in the temperature range of 313.2 to 413.2 K and pressure range of 5.0 to 25.0 MPa by the equipment. Then the viscosities of [bmim][PF6] + CO2 binary system at constant temperature, constant pressure, and different temperature and pressure were correlated, respectively. For the correlation at different tempera- ture and different t3ressure for different concentration mixtures the average relative deviation ARD is 0.037. viscosity, falling-body viscometer, [bmim] [PF6], ionic liquid, carbon dioxide 11-3270/TQ ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 1004-9541 2210-321X |
DOI: | 10.1016/S1004-9541(13)60622-9 |