Trueness of a device for intraoral scanning to capture the angle and distance between implants in edentulous mandibular arches

The digitalization of completely edentulous arches presents limitations because of the lack of anatomic structures for best-fit alignment during the image generation process of the scanner’s software program. The purpose of this clinical study was to evaluate a new device for intraoral scanning and...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of prosthetic dentistry Vol. 128; no. 6; pp. 1310 - 1317
Main Authors Carneiro Pereira, Ana Larisse, Carvalho Porto de Freitas, Rodrigo Falcão, de Fátima Trindade Pinto Campos, Maria, Soares Paiva Tôrres, Ana Clara, Bezerra de Medeiros, Annie Karoline, da Fonte Porto Carreiro, Adriana
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.12.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The digitalization of completely edentulous arches presents limitations because of the lack of anatomic structures for best-fit alignment during the image generation process of the scanner’s software program. The purpose of this clinical study was to evaluate a new device for intraoral scanning and to analyze its usefulness in capturing the 3-dimensional (3D) position of implants in edentulous mandibular arches. The 3D positions of 40 implants in 10 participants with fixed interim mandibular prostheses were evaluated by comparing 3 scanning techniques. Images were generated in 2 experimental groups, with digital scan bodies (group SC) and with the scanning device (group SD) and in a control group (group CT) in which images were obtained by laboratory scanning of casts produced from splinted impression copings. The standard tessellation language (STL) files were superimposed by using a reverse engineering software program to measure the 3D coordinate system. Variations in implant linear displacements (Δx, Δy, and Δz), total 3D displacement (Δx2+Δy2+Δz2), and angle projections (ΔθXY, ΔθXZ, and ΔθYZ) were statistically analyzed (α=.05). The distances between the implants were also measured. The Spearman correlation coefficient (α=.05) was used to find the correlation between the 3D coordinates and the distances between the implants. Group SD had lower values for linear displacement than group SC; however, this difference was not statistically significant except for implant #2. The overall evaluation showed a significant difference with better accuracy for group SD. Concerning angular displacements, group SD showed lesser angular variation for the 3 projection planes. For the distances between the implants, significant differences were only observed for the “all” assessment in which group SD behaved similarly to group CT, while group SC showed the highest values (P<.05). No correlation was detected between the axes (x, y, and z) and the distances between the implants. The evaluated scanning device led to improved trueness for linear, angular displacements, and distances between implants in mandibular edentulous arches.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0022-3913
1097-6841
DOI:10.1016/j.prosdent.2021.02.039