A study of gas contaminants and interaction with materials in RPC closed loop systems

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study ai...

Full description

Saved in:
Bibliographic Details
Published inJournal of instrumentation Vol. 8; no. 3; pp. 1 - 9
Main Authors Colafranceschi, S, Aurilio, R, Benussi, L, Bianco, S, Passamonti, L, Piccolo, D, Pierluigi, D, Russo, A, Ferrini, M, Greci, T, Saviano, G, Vendittozzi, C, Abbrescia, M, Calabria, C
Format Journal Article
LanguageEnglish
Published 01.03.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:1748-0221
1748-0221
DOI:10.1088/1748-0221/8/03/T03008