Analogs of microgravity: the function of Schlemm’s canal, intraocular pressure and autonomic nervous during the head-down tilt test in healthy subjects

AIM: To evaluate the ocular outcomes and to elucidate possible mechanisms underlying intraocular pressure (IOP) change following the head-down tilt (HDT) test. METHODS: The study included 21 participants at the Department of Ophthalmology of Tongji Hospital. Subjects received the test of I-care tono...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of ophthalmology Vol. 14; no. 9; pp. 1419 - 1423
Main Authors Chen, Wei, Xiang, Yan, Deng, Chao-Hua, Zhang, Hong, Wang, Jun-Ming
Format Journal Article
LanguageEnglish
Published International Journal of Ophthalmology Press 18.09.2021
Press of International Journal of Ophthalmology (IJO PRESS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:AIM: To evaluate the ocular outcomes and to elucidate possible mechanisms underlying intraocular pressure (IOP) change following the head-down tilt (HDT) test. METHODS: The study included 21 participants at the Department of Ophthalmology of Tongji Hospital. Subjects received the test of I-care tonometry, enhanced depth imaging optical coherence tomography and heart rate variability (HRV) analysis before and after 15min HDT test. The lumen area of Schlemm’s canal (SCAR), IOP, HRV were calculated. RESULTS: IOP increased significantly after 20° head down position from 14.0±3.0 to 17.0±3.3 mm Hg (P<0.001). SCAR decreased from 13449.0±5454.9 μm2 at sitting condition to 9576.6±4130.9 μm2 post 15min HDT test. High frequency (HF) indices increased significantly from 1462±865 Hz at baseline to 2128±824 Hz. Heart rate (HR) decreased significantly from 76±11.48 to 70±11.52 bpm after the HDT. The linear regression analysis showed that the difference of HF and SCAR significantly correlated with each other during the HDT (R2=20%, P=0.04). CONCLUSION: These outcomes perform the first evidence of the activation of autonomic nervous system of HDT may cause the collapse of Schlemm’s canal lumen, which in turn leading to the increased IOP.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2222-3959
2227-4898
DOI:10.18240/ijo.2021.09.19