Does time of CCI measurement affect the evaluation of platelet transfusion effectiveness?
The measurement of corrected count increment at 1-h post-transfusion (CCI-1 h) of platelet concentrate (PC) transfusion is recommended, but in the revised Japanese Guideline (2017) it was changed to “after 10-min to 1-h”, following the revision of the guidelines from Western countries. Here, we aime...
Saved in:
Published in | Transfusion and apheresis science Vol. 60; no. 3; p. 103123 |
---|---|
Main Authors | , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
England
Elsevier Ltd
01.06.2021
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The measurement of corrected count increment at 1-h post-transfusion (CCI-1 h) of platelet concentrate (PC) transfusion is recommended, but in the revised Japanese Guideline (2017) it was changed to “after 10-min to 1-h”, following the revision of the guidelines from Western countries. Here, we aimed to investigate on the feasibility to apply the CCI measured at 10-min or 30-min post-transfusion as the surrogate of CCI-1 h. Peripheral blood was collected at 10-min, 30-min and 1-h post-transfusion of PC and the effectiveness of the transfusion was analyzed based on the CCI. In the period from December 2017 to February 2020, 8 patients, who received multiple PC transfusion (total 208) at our institution, were analyzed. We performed the univariate analyses to examine the relationship between CCI value and the categorical variables, p-value <0.1 was obtained for gender (p = 2.91 × 10−19), fever after transfusion (p = 0.0163). The qualitative variables, namely measurement time (p = 0.0553), also showed p-value <0.1. Using these factors as covariates in the mixed effect model, we found that the measurement time (p = 0.0007) had a significant effect on the CCI value when looking at fixed effects. Although there is a tendency for decreased CCI values with time progression, the slope of the change in the mixed model was -0.00307, indicating that the CCI difference among the 3 measurements was small. Here we provide evidence that CCI measured at 10-min and 30-min post-transfusion give results comparable to those measured at 1-h post-transfusion, under the Japanese practice of platelet transfusion, which relies on 100 % single-donor apheresis PC, and ABO-identical whenever possible. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1473-0502 1878-1683 |
DOI: | 10.1016/j.transci.2021.103123 |