The Determination of Pullout Parameters for Sand with a Geogrid

The concept of designing mechanically stabilized earth (MSE) walls is divided into internal and external stability review methods, and one of the design factors required in internal stability analysis is the frictional characteristics between soil and geogrids for civil engineering applications. Typ...

Full description

Saved in:
Bibliographic Details
Published inApplied sciences Vol. 11; no. 1; p. 355
Main Authors Park, Kyungho, Kim, Daehyeon, Park, Jongbeom
Format Journal Article
LanguageEnglish
Published Basel MDPI AG 01.01.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The concept of designing mechanically stabilized earth (MSE) walls is divided into internal and external stability review methods, and one of the design factors required in internal stability analysis is the frictional characteristics between soil and geogrids for civil engineering applications. Typical methods for evaluating the frictional characteristics between soil and geogrids include the direct shear test and pullout test. It is desirable to apply the pullout test to geogrid reinforcements for pulling out geogrids embedded in soil, to measure both the surface-frictional force and passive resistance at the same time. Pullout parameters can be significantly affected by confining the stress and tensile strength of reinforcements. In general, the pullout parameters tend to be overestimated for low confining stresses in the pullout test, and underestimated for high confining stresses. Therefore, to address these issues, this study aims to evaluate the influence of the confining stress and the tensile strength of a geogrid reinforcement in the pullout test, and to propose a reasonable method for obtaining practical pullout parameters. Based on the pullout tests, the maximum pullout force depending on the tensile strength of the geogrid reinforcement was measured for one-third of the reinforcement tensile strength, and it was ruptured when pullout force greater than the maximum pullout force was exerted. Furthermore, it was observed that, in the reinforcement pullout test, pullout force was measured in the whole area of the reinforcement at a confining stress smaller than one-half of the tensile strength of the grid. As a result, the effective confining stress method considering only the confining stress at which the reinforcement is fully pulled out to develop the pullout characteristics can be a practical method for obtaining pullout parameters without regard to the reinforcement tensile strength.
ISSN:2076-3417
2076-3417
DOI:10.3390/app11010355