Pulmonary nodule detection on MDCT images: evaluation of diagnostic performance using thin axial images, maximum intensity projections, and computer-assisted detection

This study aimed at evaluating the diagnostic benefits of maximum intensity projections (MIP) and a commercially available computed-assisted detection system (CAD) for the detection of pulmonary nodules on MDCT as compared with standard 1-mm images on lung cancer screening material. Thirty subjects...

Full description

Saved in:
Bibliographic Details
Published inEuropean radiology Vol. 17; no. 12; pp. 3148 - 3156
Main Authors Jankowski, A., Martinelli, T., Timsit, J. F., Brambilla, C., Thony, F., Coulomb, M., Ferretti, G.
Format Journal Article
LanguageEnglish
Published Germany Springer Nature B.V 01.12.2007
Springer Verlag
Subjects
Online AccessGet full text
ISSN0938-7994
1432-1084
DOI10.1007/s00330-007-0727-6

Cover

Loading…
More Information
Summary:This study aimed at evaluating the diagnostic benefits of maximum intensity projections (MIP) and a commercially available computed-assisted detection system (CAD) for the detection of pulmonary nodules on MDCT as compared with standard 1-mm images on lung cancer screening material. Thirty subjects were randomly selected from our database. Three radiologists independently reviewed three types of images: axial 1-mm images, axial MIP slabs, and CAD system detections. Two independent experienced chest radiologists decided which were true-positive nodules. Two hundred eighty-five nodules > or =1 mm were identified as true-positive by consensus of two independent chest radiologists. The detection rates of the three independent observers with 1-mm axial images were 22 +/- 4.8%, 30 +/- 5.3%, and 47 +/- 2.8%; with MIP: 33 +/- 5.4%, 39 +/- 5.7%, and 45 +/- 5.8%; and with CAD: 35 +/- 5.6%, 36 +/- 5.6%, and 36 +/- 5.6%. There was a reading technique effect on the observers' sensitivity for nodule detection: sensitivities with MIP were higher than with 1-mm images or CAD for all nodules (F-values = 0.046). For nodules > or =3 mm, readers' sensitivities were higher with 1-mm images or MIP than with CAD (p < 0.0001). CAD was the most and MIP the less time-consuming technique (p < 0.0001). MIP and CAD reduced the number of overlooked small nodules. As MIP is more sensitive and less time consuming than the CAD we used, we recommend viewing MIP and 1-mm images for the detection of pulmonary nodules.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0938-7994
1432-1084
DOI:10.1007/s00330-007-0727-6