Feasibility, safety, and efficacy of iron bioresorbable scaffold in neonates with duct-dependent pulmonary circulation
Introduction: Bioresorbable stent has the theoretical advantage in the pediatric age group; however, experience in the literature is very limited. Objectives: This pilot study sought to evaluate the feasibility, safety, and performance of iron bioresorbable scaffold (IBS Angel™) as short-term pallia...
Saved in:
Published in | Annals of pediatric cardiology Vol. 15; no. 2; pp. 147 - 153 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
India
Wolters Kluwer - Medknow
01.03.2022
Wolters Kluwer Medknow Publications |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Introduction: Bioresorbable stent has the theoretical advantage in the pediatric age group; however, experience in the literature is very limited. Objectives: This pilot study sought to evaluate the feasibility, safety, and performance of iron bioresorbable scaffold (IBS Angel™) as short-term palliation in lesions with noncomplex patent ductus arteriosus (PDA). Materials and Methods: Nine neonates with duct dependent but dual-source pulmonary blood flow (PBF) were included. Major stent-related complications, in-hospital course, stent patency up to 6 months, and unplanned re-interventions were studied, as well the percentage of stent material resorbed in patients in whom the stents were explanted at the surgery. Results: IBS Angel™ was successfully implanted in all nine patients (mean weight range 3.4 ± 0.4 kg). Six were pulmonary atresia with an intact ventricular septum and 1 critical pulmonary stenosis patients where PDA stenting was done together or after balloon dilation. The mean procedure and fluoroscopy times were 89 ± 39 min and 16.3 ± 6.9 min, respectively. There were no major complications such as stent thrombosis or embolization and there were no in-hospital deaths. Post procedure overshunting and prolonged ventilatory support was a prominent feature. The median ventilation days was 3 (1–11 days). One patient died after 1 month due to respiratory syncytial virus pneumonia at the referring hospital. At 6 months follow-up, four had patent stents and four had blocked or restrictive stent flow. One patient received re-stenting at 4 months for restrictive stent flow. In three patients where microcomputed tomography of explanted stent was available, resorption of iron was 15% at 6 months and >65% at 16 months. Conclusions: Ductal stenting with IBS Angel™ is feasible and safe in selected patients. Because of early luminal loss, its use may be recommended for lesions with dual-source PBF with noncomplex PDA morphology that requires a short duration of palliation. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0974-2069 0974-5149 |
DOI: | 10.4103/apc.apc_187_21 |