Platelet-function analyzer closure times indicate shear stress-induced hemostatic abnormalities in patients with aortic valve stenosis and correlate with perioperative transfusion requirements

Background: Shear stress-induced hemostatic abnormalities are highly prevalent in patients with aortic valve stenosis. In this study, we determined closure times with a platelet-function analyzer (PFA-100, Dade Behring, Marburg, Germany) in patients admitted for aortic valve replacement to assess th...

Full description

Saved in:
Bibliographic Details
Published inPerfusion Vol. 25; no. 3; pp. 153 - 158
Main Authors Sucker, C., Zotz, RB, Kurt, M., Feindt, P., Litmathe, J.
Format Journal Article
LanguageEnglish
Published London, England SAGE Publications 01.05.2010
Sage Publications Ltd
Subjects
Online AccessGet full text
ISSN0267-6591
1477-111X
1477-111X
DOI10.1177/0267659110369853

Cover

Loading…
More Information
Summary:Background: Shear stress-induced hemostatic abnormalities are highly prevalent in patients with aortic valve stenosis. In this study, we determined closure times with a platelet-function analyzer (PFA-100, Dade Behring, Marburg, Germany) in patients admitted for aortic valve replacement to assess the correlation with the severity of aortic valve stenosis, blood loss, perioperative transfusion requirements, and need for re-thoracotomy. Patients and Methods: Fifty consecutive patients (mean age [± SD] 68 ± 9 years) were enrolled. Closure times of epinephrin/collagen and adenosine diphosphate (ADP)/collagen cartridges were determined at least ten days after discontinuation of antiplatelet medication and compared to those of healthy control subjects without medication. Results: Closure times of epinephrin/collagen (210 ± 69 sec vs. 140 ± 50 sec, p < 0.0001) and ADP/collagen (145 ± 58 sec vs. 108 ± 45 sec, p < 0.0001) cartridges were prolonged in patients with aortic valve stenosis. Intraoperative transfusion of red blood cell units was associated with the closure times of epinephrin/collagen (r = 0.28, p = 0.04) and ADP/ collagen cartridges (r = 0.28, p = 0.04). Total transfusion of red blood cell units was associated with ADP/ collagen closure times (r = 0.31, p = 0.02), but not epinephrin/collagen closure times (r = 0.26, p = 0.07). No significant association of closure times with intraoperative, postoperative and total transfusion of fresh frozen plasma units was observed. Conclusions: Prolongation of closure times determined with a platelet-function analyzer is highly prevalent in patients with aortic valve stenosis and appears to reflect shear stress-induced hemostatic abnormalities. Since prolonged closure times are associated with increased perioperative transfusion of red blood cell units, the assay could significantly contribute to the identification of individuals at risk.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0267-6591
1477-111X
1477-111X
DOI:10.1177/0267659110369853