Theoretical analysis of a transdermal ferromagnetic implant for retention of magnetic drug carrier particles

The use of a ferromagnetic wire implant placed near an artery to assist the collection of magnetic drug carrier particles (MDCPs) using an external magnet is theoretically studied. Three magnetic drug targeting (MDT) systems are evaluated in terms of their MDCP collection efficiency (CE): a permanen...

Full description

Saved in:
Bibliographic Details
Published inJournal of magnetism and magnetic materials Vol. 293; no. 1; pp. 605 - 615
Main Authors Avilés, Misael O., Ebner, Armin D., Chen, Haitao, Rosengart, Axel J., Kaminski, Michael D., Ritter, James A.
Format Journal Article Conference Proceeding
LanguageEnglish
Published Amsterdam Elsevier B.V 01.05.2005
Elsevier Science
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The use of a ferromagnetic wire implant placed near an artery to assist the collection of magnetic drug carrier particles (MDCPs) using an external magnet is theoretically studied. Three magnetic drug targeting (MDT) systems are evaluated in terms of their MDCP collection efficiency (CE): a permanent magnet and wire is better than a permanent magnet alone, which is better than a homogeneous magnetic field and wire.