Reliability of Quantitative Assessment of Distal Radioulnar Joint Stability With Force‐Monitor Ultrasonography

ABSTRACT The purpose of this study was to evaluate the reliability of ultrasound assessment of the displacement–force relationships for distal radioulnar joint (DRUJ) stability. Non‐dominant wrists of 10 healthy male subjects were evaluated by force‐monitor ultrasonography. This apparatus was develo...

Full description

Saved in:
Bibliographic Details
Published inJournal of orthopaedic research Vol. 37; no. 9; pp. 2053 - 2060
Main Authors Yuine, Hiroshi, Yoshii, Yuichi, Tung, Wen‐lin, Ishii, Tomoo, Shiraishi, Hideki
Format Journal Article
LanguageEnglish
Published United States 01.09.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:ABSTRACT The purpose of this study was to evaluate the reliability of ultrasound assessment of the displacement–force relationships for distal radioulnar joint (DRUJ) stability. Non‐dominant wrists of 10 healthy male subjects were evaluated by force‐monitor ultrasonography. This apparatus was developed to apply cyclic compression to the wrist with pre‐determined transducer displacement conditions in the range of 0.1–3.0 mm. The subject's wrist was placed on the table with the forearm in the pronated position. The transducer was placed on the dorsal surface of the distal radius and ulna, perpendicular to the long axis of the forearm. The center of the ulnar head was at the DRUJ level. The distance between the dorsal surface of the distal radius and the ulnar head was measured at an initial and a pressed‐down position. Changes in radioulnar displacement, force to the wrist and the displacement/force ratio were evaluated. The measurements were performed independently by two raters. The intra‐class correlation coefficients (ICCs) for the radioulnar displacement were 0.76, 0.68, and 0.93, in the 1.0, 2.0, and 3.0 mm transducer displacement conditions, respectively. The ICCs for the force to the wrist were 0.18, 0.67, and 0.34, in different transducer displacement conditions, respectively. The ICCs for the displacement/force ratios were 0.68, 0.67, and 0.97, in different transducer displacement conditions, respectively. The highest ICC for the radioulnar displacement and the displacement/force ratio was observed in the 3.0 mm displacement condition. This assessment of displacement–force relationships may be useful to quantify DRUJ stability. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:2053–2060, 2019
Bibliography:Conflicts of interest: None.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0736-0266
1554-527X
1554-527X
DOI:10.1002/jor.24331