Multilayer-based soft X-ray polarimeter at the Beijing Synchrotron Radiation Facility
A compact high precision eight-axis automatism and two-axis manual soft-ray polarimeter with a multi- layer has been designed, constructed, and installed in 3WlB at the Beijing Synchrotron Radiation Facility (BSRF). Four operational modes in the same device, which are double-reflection, double-trans...
Saved in:
Published in | Chinese physics C Vol. 37; no. 7; pp. 83 - 87 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
01.07.2013
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A compact high precision eight-axis automatism and two-axis manual soft-ray polarimeter with a multi- layer has been designed, constructed, and installed in 3WlB at the Beijing Synchrotron Radiation Facility (BSRF). Four operational modes in the same device, which are double-reflection, double-transmission, front-reflection-behind- transmission and front-transmission-behind-reflection, have been realized. It can be used for the polarization analysis of synchrotron radiation. It also can be used to characterize the polarization properties of the optical elements in the soft X-ray energy range. Some experiments with Mo/Si and Cr/C multilayers have been performed by using this polarimeter with good results obtained. |
---|---|
Bibliography: | 11-5641/O4 A compact high precision eight-axis automatism and two-axis manual soft-ray polarimeter with a multi- layer has been designed, constructed, and installed in 3WlB at the Beijing Synchrotron Radiation Facility (BSRF). Four operational modes in the same device, which are double-reflection, double-transmission, front-reflection-behind- transmission and front-transmission-behind-reflection, have been realized. It can be used for the polarization analysis of synchrotron radiation. It also can be used to characterize the polarization properties of the optical elements in the soft X-ray energy range. Some experiments with Mo/Si and Cr/C multilayers have been performed by using this polarimeter with good results obtained. SUN Li-Juan,CUI Ming-Qi, ZHU Jie, ZHAO Yi-Dong, ZHENG Lei, WANG Zhan-Shan, ZHU Jing-Tao( 1 State Key Laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China 2 Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China 3 Tongji University, Shanghai 200092, China) synchrotron radiation, multilayer, polarimeter, soft X-ray ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 1674-1137 0254-3052 |