Multilayer-based soft X-ray polarimeter at the Beijing Synchrotron Radiation Facility

A compact high precision eight-axis automatism and two-axis manual soft-ray polarimeter with a multi- layer has been designed, constructed, and installed in 3WlB at the Beijing Synchrotron Radiation Facility (BSRF). Four operational modes in the same device, which are double-reflection, double-trans...

Full description

Saved in:
Bibliographic Details
Published inChinese physics C Vol. 37; no. 7; pp. 83 - 87
Main Author 孙立娟 崔明启 朱杰 赵屹东 郑雷 王占山 朱京涛
Format Journal Article
LanguageEnglish
Published 01.07.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A compact high precision eight-axis automatism and two-axis manual soft-ray polarimeter with a multi- layer has been designed, constructed, and installed in 3WlB at the Beijing Synchrotron Radiation Facility (BSRF). Four operational modes in the same device, which are double-reflection, double-transmission, front-reflection-behind- transmission and front-transmission-behind-reflection, have been realized. It can be used for the polarization analysis of synchrotron radiation. It also can be used to characterize the polarization properties of the optical elements in the soft X-ray energy range. Some experiments with Mo/Si and Cr/C multilayers have been performed by using this polarimeter with good results obtained.
Bibliography:11-5641/O4
A compact high precision eight-axis automatism and two-axis manual soft-ray polarimeter with a multi- layer has been designed, constructed, and installed in 3WlB at the Beijing Synchrotron Radiation Facility (BSRF). Four operational modes in the same device, which are double-reflection, double-transmission, front-reflection-behind- transmission and front-transmission-behind-reflection, have been realized. It can be used for the polarization analysis of synchrotron radiation. It also can be used to characterize the polarization properties of the optical elements in the soft X-ray energy range. Some experiments with Mo/Si and Cr/C multilayers have been performed by using this polarimeter with good results obtained.
SUN Li-Juan,CUI Ming-Qi, ZHU Jie, ZHAO Yi-Dong, ZHENG Lei, WANG Zhan-Shan, ZHU Jing-Tao( 1 State Key Laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China 2 Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China 3 Tongji University, Shanghai 200092, China)
synchrotron radiation, multilayer, polarimeter, soft X-ray
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1674-1137
0254-3052
DOI:10.1088/1674-1137/37/7/078001