R/S Ratio in Lead III Predicts Successful Ablation of Ventricular Arrhythmias Originating in Para-Hisian Region

The aim of this study was to investigate the electrocardiographic characteristics of ventricular arrhythmias (VAs) originating near the His bundle (HB) and use the R/S ratio in lead III (RIII/SIII ratio) to predict successful ablation of para-Hisian VAs. Catheter ablation for idiopathic VAs near the...

Full description

Saved in:
Bibliographic Details
Published inJACC. Clinical electrophysiology Vol. 7; no. 6; pp. 719 - 730
Main Authors Yue-Chun, Li, Yuan-Nan, Lin, Jing, Xu, Yang-Qi, Pan, Cheng, Zheng, Yang-Jing, Xue, Jia-Xuan, Lin, Jin, Li, Jia, Li, Jia-Feng, Lin
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.06.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The aim of this study was to investigate the electrocardiographic characteristics of ventricular arrhythmias (VAs) originating near the His bundle (HB) and use the R/S ratio in lead III (RIII/SIII ratio) to predict successful ablation of para-Hisian VAs. Catheter ablation for idiopathic VAs near the HB is often challenging, and data are limited. The present study included 134 consecutive patients undergoing catheter ablation of para-Hisian VAs. The electrocardiographic characteristics in these patients were retrospectively evaluated with successful ablation and failed ablation. Successful ablation was achieved in 115 (85.8%) of the 134 patients. There was no significant difference in QRS duration between the successful and the failed ablation groups. The ablation success rate was significantly lower for para-Hisian VAs with a predominantly positive R wave in lead III than those with a predominantly negative S wave in lead III. The significant factor associated with successful ablation was the RIII/SIII ratio. The RIII/SIII ratio ≤1.1 predicted the successful ablation of para-Hisian VAs with high sensitivity (80.9%) and specificity (94.7%). The RIII/SIII ratio of >1.2 had high sensitivity (100.0%) and specificity (82.8%) to predict the distance <5 mm from the site of origin of para-Hisian VAs to the site recording the largest HB potential. The RIII/SIII ratio was a helpful predictor of the successful ablation of VAs originating in the vicinity of the HB. This may be useful for planning ablation of para-Hisian VAs and minimizing the risk of inadvertent atrioventricular block. [Display omitted]
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2405-500X
2405-5018
DOI:10.1016/j.jacep.2020.10.012