Skull fracture prediction through subject-specific finite element modelling is highly sensitive to model parameters

Reliable computer models are needed for a better understanding of the physical mechanisms of skull fracture in accidental hits, falls, bicycle - motor vehicle & car accidents and assaults. The performance and biofidelity of these models depend on the correct anatomical representation and materia...

Full description

Saved in:
Bibliographic Details
Published inJournal of the mechanical behavior of biomedical materials Vol. 100; p. 103384
Main Authors De Kegel, Dries, Meynen, Alexander, Famaey, Nele, Harry van Lenthe, G., Depreitere, Bart, Sloten, Jos Vander
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier Ltd 01.12.2019
Subjects
Online AccessGet full text
ISSN1751-6161
1878-0180
1878-0180
DOI10.1016/j.jmbbm.2019.103384

Cover

Loading…
More Information
Summary:Reliable computer models are needed for a better understanding of the physical mechanisms of skull fracture in accidental hits, falls, bicycle - motor vehicle & car accidents and assaults. The performance and biofidelity of these models depend on the correct anatomical representation and material description of these structures. In literature, a strain energy criterion has been proposed to predict skull fractures. However, a broad range of values for this criterion has been reported. This study investigates if the impactor orientation, scalp thickness and material model of the skull could provide us with insight in the influencing factors of this criterion. 18 skull fracture experiments previously performed in our research group were reproduced in finite element simulations. Subject-specific skull geometries were derived from medical images and used to create high-quality finite element meshes. Based on local Hounsfield units, a subject-specific isotropic material model was assigned. The subject-specific models were able to predict fractures who matched visually with the corresponding experimental fracture patterns and provided detailed fracture patterns. The sensitivity study showed that small variations in impactor positioning as well as variations of the local geometry (frontal-temporal-occipital) strongly influenced the skull strain energy. Subject-specific modelling leads to a more accurate prediction of the force-displacement curve. The average error of the peak fracture force for all the 18 cases is 0.4190 for the subject-specific and 0.4538 for the homogeneous material model, for the displacement; 0.3368 versus 0.3844. But it should be carefully interpreted as small variations in the computational model significantly influence the outcome.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1751-6161
1878-0180
1878-0180
DOI:10.1016/j.jmbbm.2019.103384