Comparison of CK-MB fractionation by antibody inhibition reaction and DEAE-Sephadex chromatography

1. CK-MB isoenzyme fractionation has been compared between DEAE-sephadex chromatography and the CK-M-subunit inhibiting antibody procedure. 2. It was found that the inhibiting antibody method generally gave lower values than the chromatography procedure. 3. The above difference can be partially attr...

Full description

Saved in:
Bibliographic Details
Published inClinical biochemistry Vol. 11; no. 4; pp. 175 - 178
Main Authors Itiaba, K., Crawhall, J.C.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.01.1978
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:1. CK-MB isoenzyme fractionation has been compared between DEAE-sephadex chromatography and the CK-M-subunit inhibiting antibody procedure. 2. It was found that the inhibiting antibody method generally gave lower values than the chromatography procedure. 3. The above difference can be partially attributed to inhibitory factors in the antibody system. 4. It was concluded that although there was general agreement between the two procedures, the CK-M-subunit inhibiting antibody procedure should be viewed with caution at low creatine kinase activities, and should never be done without the appropriate reagent blanks.