Evaluation of the materials properties, stability and cell response of a range of PEGDMA hydrogels for tissue engineering applications
The main aim of this study was to examine the stability of a range of polyethyleneglycol dimethacrylate (PEGDMA) hydrogels over a 28-day period in simulated physiological solution. Upon optimisation of the ultraviolet (UV) curing conditions, the PEGDMA hydrogels were prepared using four different mo...
Saved in:
Published in | Journal of the mechanical behavior of biomedical materials Vol. 99; pp. 1 - 10 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Netherlands
Elsevier Ltd
01.11.2019
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The main aim of this study was to examine the stability of a range of polyethyleneglycol dimethacrylate (PEGDMA) hydrogels over a 28-day period in simulated physiological solution. Upon optimisation of the ultraviolet (UV) curing conditions, the PEGDMA hydrogels were prepared using four different monomer concentrations (25, 50, 75 and 100 wt% PEGDMA) in water and cross-linked by photopolymerisation. Initial results revealed a correlation between monomer concentration and swelling behaviour, where a decrease in swelling was observed with increase in monomer content. On storage in physiological solutions at 37 °C, a decrease in the weight remaining of the hydrogels and the pH of the solutions was observed over a 28-day period. Using scanning electron microscopy, the surface topography of the hydrogels appeared to get smoother and in parallel changes in hydrophilicty were observed, with the biggest changes observed for the higher monomer concentrations where water contact angle values were seen to increase toward 90°. However, the mechanical properties remained relatively unaffected and there was no adverse effect on cell metabolic activity observed for cells grown in the presence of PEGDMA samples or using elution methods. Looking at the combination of mechanical chemical and thermal properties shown these results are an important finding for scaffolds intended for tissue engineering applications, where provision of mechanical support without the elicitation of an inflammatory response due to polymer degradation products is crucial for successful integration and neotissue formation during the first 28 days post implantation.
[Display omitted] |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1751-6161 1878-0180 |
DOI: | 10.1016/j.jmbbm.2019.07.003 |