Effect of Particles on NOx Emission of Triple Coaxial Tube Burner in a Riser for Waste Liquid Incineration
Waste liquid incineration using a triple coaxial tube burner in a riser with upper stream is proposed. The effect of hold up of FCC particles on NOx concentration in the burnt gas and conversion of nitrogen in the model waste liquid into NOx is experimentally studied. The experimental results show t...
Saved in:
Published in | KAGAKU KOGAKU RONBUNSHU Vol. 25; no. 6; pp. 1030 - 1032 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | Japanese English |
Published |
The Society of Chemical Engineers, Japan
1999
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Waste liquid incineration using a triple coaxial tube burner in a riser with upper stream is proposed. The effect of hold up of FCC particles on NOx concentration in the burnt gas and conversion of nitrogen in the model waste liquid into NOx is experimentally studied. The experimental results show that the region in which NOx is generated is almost independent of the existence of the particles. However, a rise in the hold up of the particles reduces NOx emission in the exhaust gas. The behavior of the NOx emission can be summarized by applying Fenimore's correlation. |
---|---|
ISSN: | 0386-216X 1349-9203 |
DOI: | 10.1252/kakoronbunshu.25.1030 |