Prediction of Acute Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy Using Dose-Volume Parameters From Functional Mapping on Gallium 68 Perfusion Positron Emission Tomography/Computed Tomography

The aim of this work was to compare anatomic and functional dose-volume parameters as predictors of acute radiation-induced lung toxicity (RILT) in patients with lung tumors treated with stereotactic body radiation therapy. Fifty-nine patients treated with stereotactic body radiation therapy were pr...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of radiation oncology, biology, physics Vol. 118; no. 4; pp. 952 - 962
Main Authors Lucia, François, Bourhis, David, Pinot, Fanny, Hamya, Mohamed, Goasduff, Gaëlle, Blanc-Béguin, Frédérique, Hennebicq, Simon, Mauguen, Maëlle, Kerleguer, Kevin, Schick, Ulrike, Consigny, Maëlys, Pradier, Olivier, Le Gal, Grégoire, Salaun, Pierre-Yves, Bourbonne, Vincent, Le Roux, Pierre-Yves
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 15.03.2024
Online AccessGet full text

Cover

Loading…
More Information
Summary:The aim of this work was to compare anatomic and functional dose-volume parameters as predictors of acute radiation-induced lung toxicity (RILT) in patients with lung tumors treated with stereotactic body radiation therapy. Fifty-nine patients treated with stereotactic body radiation therapy were prospectively included. All patients underwent gallium 68 lung perfusion positron emission tomography (PET)/computed tomography (CT) imaging before treatment. Mean lung dose (MLD) and volumes receiving x Gy (VxGy, 5-30 Gy) were calculated in 5 lung volumes: the conventional anatomic volume (AV) delineated on CT images, 3 lung functional volumes (FVs) defined on lung perfusion PET imaging (FV50%, FV70%, and FV90%; ie, the minimal volume containing 50%, 70%, and 90% of the total activity within the AV), and a low FV (LFV; LFV = AV − FV90%). The primary endpoint of this analysis was grade ≥2 acute RILT at 3 months as assessed with National Cancer Institute Common Terminology Criteria for Adverse Events version 5. Dose-volume parameters in patients with and without acute RILT were compared. Receiver operating characteristic curves assessing the ability of dose-volume parameters to discriminate between patients with and without acute RILT were generated, and area under the curve (AUC) values were calculated. Of the 59 patients, 10 (17%) had grade ≥2 acute RILT. The MLD and the VxGy in the AV and LFV were not statistically different between patients with and without acute RILT (P > .05). All functional parameters were significantly higher in acute RILT patients (P < .05). AUC values (95% CI) for MLD AV, LFV, FV50%, FV70%, and FV90% were 0.66 (0.46-0.85), 0.60 (0.39-0.80), 0.77 (0.63-0.91), 0.77 (0.64-0.91), and 0.75 (0.58-0.91), respectively. AUC values for V20Gy AV, LFV, FV50%, FV70%, and FV90% were 0.65 (0.44-0.87), 0.64 (0.46-0.83), 0.82 (0.69-0.95), 0.81 (0.67-0.96), and 0.75 (0.57-0.94), respectively. The predictive value of PET perfusion-based functional parameters outperforms the standard CT-based dose-volume parameters for the risk of grade ≥2 acute RILT. Functional parameters could be useful for guiding radiation therapy planning and reducing the risk of acute RILT.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0360-3016
1879-355X