CorVue algorithm efficacy to predict heart failure in real life: Unnecessary and potentially misleading information?

Background Heart failure (HF) hospitalizations have a negative impact on quality of life and imply important costs. Intrathoracic impedance (ITI) variations detected by cardiac devices have been hypothesized to predict HF hospitalizations. Although Optivol™ algorithm (Medtronic, Minneapolis, MN, USA...

Full description

Saved in:
Bibliographic Details
Published inPacing and clinical electrophysiology Vol. 41; no. 8; pp. 948 - 952
Main Authors Palfy, Julia Anna, Benezet‐Mazuecos, Juan, Martinez Milla, Juan, Iglesias, Jose Antonio, la Vieja, Juan Jose, Sanchez‐Borque, Pepa, Miracle, Angel, Rubio, Jose Manuel
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.08.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background Heart failure (HF) hospitalizations have a negative impact on quality of life and imply important costs. Intrathoracic impedance (ITI) variations detected by cardiac devices have been hypothesized to predict HF hospitalizations. Although Optivol™ algorithm (Medtronic, Minneapolis, MN, USA) has been widely studied, CorVue™ algorithm's (St. Jude Medical, St. Paul, MN, USA) long‐term efficacy has not been systematically evaluated in a “real‐life” cohort. Methods CorVue™ was activated in implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT‐D) patients to store information about ITI measures. Clinical events (new episodes of HF requiring treatment and hospitalizations) and CorVue™ data were recorded every 3 months. Appropriate CorVue™ detection for HF was considered if it occurred in the 4 prior weeks to the clinical event. Results Fifty‐three ICD/CRT‐D (26 ICD and 27 CRT‐D) patients (67 ± 1 years old, 79% male) were included. Device position was subcutaneous in 28 patients. At inclusion, mean left ventricular ejection fraction was 25 ± 7% and 27 patients (51%) were in New York Heart Association class I, 18 (34%) in class II, and eight (15%) in class III. After a mean follow‐up of 17 ± 9 months, 105 ITI drops alarms were detected in 32 patients (60%). Only six alarms were appropriate (true positive) and required hospitalization. Eighteen patients (34%) presented 25 clinical episodes (12 hospitalizations and 13 emergency room/ambulatory treatment modifications). Nineteen of these clinical episodes (76%) remained undetected by the CorVue™ (false negative). Sensitivity of CorVue™ resulted in 24%, specificity was 70%, positive predictive value of 6%, and negative predictive value of 93%. Conclusions CorVue™ showed a low sensitivity to predict HF events. Therefore, routinely activation of this algorithm could generate misleading information.
Bibliography:Disclosure
None of the authors has received financial support for the present study.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0147-8389
1540-8159
DOI:10.1111/pace.13399