Comparison of Post Space Volume Changes Following Fiber Post Removal Using Er,Cr:YSGG Laser Versus Ultrasonic Instrument

Purpose The purpose of this in vitro study was to compare the post space volume changes following removal of glass fiber posts in endodontically treated teeth by using erbium, chromium:yttrium‐scandium‐gallium‐garnet (Er,Cr:YSGG) laser to the conventional ultrasonic method. Materials and Methods Twe...

Full description

Saved in:
Bibliographic Details
Published inJournal of prosthodontics Vol. 31; no. 3; pp. 245 - 251
Main Authors Cho, Juyeon, Liu, Jie, Bukhari, Esraa A., Zheng, Fengyuan, Kim, Do‐Gyoon, Lee, Damian J.
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.03.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose The purpose of this in vitro study was to compare the post space volume changes following removal of glass fiber posts in endodontically treated teeth by using erbium, chromium:yttrium‐scandium‐gallium‐garnet (Er,Cr:YSGG) laser to the conventional ultrasonic method. Materials and Methods Twelve single‐root human extracted teeth were cut into 13 mm near cementoenamel junction (CEJ), and then underwent endodontic treatment. The post spaces were prepared to 8 mm in length. Glass fiber posts were inserted with self‐curing resin cement. Specimens were randomly assigned to laser or ultrasonic methods for their post removal. Post space volumes were measured using microcomputed tomography (micro‐CT) before post cementation and after post removal. Dentin thickness was measured after post removal at coronal, middle, and apical third of the root canal space. Paired t‐test and t‐test were used to compare space volumes between before post cementation and after post removal, and between laser and ultrasonic groups, respectively. Results Six specimens were tested for each group. The average volume change was 6.499 mm3 in laser and 7.418 mm3 in ultrasonic method. There was not a significant difference between laser and ultrasonic group in respect of post space volume changes (p = 0.71). Both methods showed significant volume increase following post removal (p < 0.05). Significantly less dentin was lost when laser was used for post removal in the coronal portion of the post space (p = 0.002). Conclusions Er,Cr:YSGG laser can be used as effective option, comparable to the conventional ultrasonic method when removing posts in endodontically treated teeth. Laser has the potential to provide conservative post removal.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
ObjectType-News-3
content type line 23
ISSN:1059-941X
1532-849X
DOI:10.1111/jopr.13391