Doppler Parameters Derived from Transthoracic Echocardiography Accurately Detect Bioprosthetic Mitral Valve Dysfunction

Detecting bioprosthetic mitral valve dysfunction on transthoracic echocardiography can be challenging because of acoustic shadowing of regurgitant jets and a wide normal range of transvalvular gradients. Several studies in mechanical mitral valves have demonstrated the utility of the transthoracical...

Full description

Saved in:
Bibliographic Details
Published inJournal of the American Society of Echocardiography Vol. 30; no. 10; pp. 966 - 973.e1
Main Authors Spencer, Ryan J., Gin, Ken G., Tsang, Michael Y.C., Tsang, Teresa S.M., Nair, Parvathy, Lee, Pui K., Jue, John
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.10.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Detecting bioprosthetic mitral valve dysfunction on transthoracic echocardiography can be challenging because of acoustic shadowing of regurgitant jets and a wide normal range of transvalvular gradients. Several studies in mechanical mitral valves have demonstrated the utility of the transthoracically derived parameters E (peak early mitral inflow velocity), pressure half-time, and the ratio of mitral inflow velocity-time integral (VTIMV) to left ventricular outflow tract velocity-time integral (VTILVOT) in detecting significant prosthetic dysfunction. Uncertainty exists as to their applicability and appropriate cutoff levels in bioprosthetic valves. This study was designed to establish the accuracy and appropriate normal limits of routinely collected transthoracic Doppler parameters when used to assess bioprosthetic mitral valve function. A total of 135 clinically stable patients with bioprosthetic mitral valves who had undergone both transthoracic and transesophageal echocardiography within a 6-month period were retrospectively identified from the past 11 years of the echocardiography database. Transthoracic findings were labeled as normal (n = 81), regurgitant (n = 44), or stenotic (n = 10) according to the patient's transesophageal echocardiographic findings. Univariate and multivariate analyses were performed to identify Doppler parameters that detected dysfunction; then receiver operating characteristic curves were created to establish appropriate normal cutoff levels. The VTIMV/VTILVOT ratio was the most accurate Doppler parameter at detecting valvular dysfunction, with a ratio of >2.5 providing sensitivity of 100% and specificity of 95%. E > 1.9 m/sec was slightly less accurate (93% sensitivity, 72% specificity), while a pressure half-time of >170 msec had both 100% specificity and sensitivity for detecting significant bioprosthetic mitral valve stenosis, (although it did not differentiate between regurgitant and normal). This study demonstrates that Doppler parameters derived from transthoracic echocardiography can accurately detect bioprosthetic mitral valve dysfunction. These parameters, particularly a VTIMV/VTILVOT ratio of >2.5, are a sensitive way of selecting patients to undergo more invasive examination with transesophageal echocardiography. •Transthoracic Doppler parameters identify dysfunctional mechanical mitral valves.•The authors examined these parameters in normal and abnormal bioprosthetic mitral valves.•The VTIMV/VTILVOT ratio was best at identifying valvular dysfunction.•VTIMV/VTILVOT > 2.5 was 100% sensitive for bioprosthetic mitral valve dysfunction.•VTIMV/VTILVOT > 2.5 was 95% specific for bioprosthetic mitral valve dysfunction.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0894-7317
1097-6795
DOI:10.1016/j.echo.2017.06.022