Performance evaluation of an HTS transformer using finite element method

This paper presents the performance evaluation of an HTS transformer. The design of the transformer was based on the BSCCO-2223 HTS tapes and double pancake windings. A total of four double pancake windings were used. Two of the windings were connected in series for the high voltage winding and two...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on applied superconductivity Vol. 10; no. 1; pp. 857 - 860
Main Authors JUNGWOOK SIM, GUEESOO CHA, LEE, J.-K, LEE, Y.-W, HAHN, S.-Y, CHOI, K.-D
Format Journal Article Conference Proceeding
LanguageEnglish
Published New York, NY IEEE 01.03.2000
Institute of Electrical and Electronics Engineers
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This paper presents the performance evaluation of an HTS transformer. The design of the transformer was based on the BSCCO-2223 HTS tapes and double pancake windings. A total of four double pancake windings were used. Two of the windings were connected in series for the high voltage winding and two windings were connected in parallel for the low voltage winding. The characteristics of several winding arrangements were examined. The performance of the transformer during transient, which is caused by a sudden short circuit, was simulated. The current limiting effect, temperature rise and resistance growth of the superconducting winding were also shown.
Bibliography:SourceType-Scholarly Journals-2
ObjectType-Feature-2
ObjectType-Conference Paper-1
content type line 23
SourceType-Conference Papers & Proceedings-1
ObjectType-Article-3
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
ISSN:1051-8223
1558-2515
DOI:10.1109/77.828366