Midterm Survivorship and Patient Satisfaction of Robotic-Arm-Assisted Medial Unicompartmental Knee Arthroplasty: A Multicenter Study

Studies have showed improved accuracy of lower leg alignment, precise component position, and soft-tissue balance with robotic-assisted unicompartmental knee arthroplasty (UKA). No studies, however, have assessed the effect on midterm survivorship. Therefore, the purpose of this prospective, multice...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of arthroplasty Vol. 33; no. 6; pp. 1719 - 1726
Main Authors Kleeblad, Laura J., Borus, Todd A., Coon, Thomas M., Dounchis, Jon, Nguyen, Joseph T., Pearle, Andrew D.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.06.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Studies have showed improved accuracy of lower leg alignment, precise component position, and soft-tissue balance with robotic-assisted unicompartmental knee arthroplasty (UKA). No studies, however, have assessed the effect on midterm survivorship. Therefore, the purpose of this prospective, multicenter study was to determine midtem survivorship, modes of failure, and satisfaction of robotic-assisted medial UKA. A total of 473 consecutive patients (528 knees) underwent robotic-arm-assisted medial UKA surgery at 4 separate institutions between March 2009 and December 2011. All patients received a fixed-bearing, metal-backed onlay tibial component. Each patient was contacted at minimum 5-year follow-up and asked a series of questions to determine survival and satisfaction. Kaplan-Meier method was used to determine survivorship. Data were collected for 384 patients (432 knees) with a mean follow-up of 5.7 years (5.0-7.7). The follow-up rate was 81.2%. In total, 13 revisions were performed, of which 11 knees were converted to total knee arthroplasty and in 2 cases 1 UKA component was revised, resulting in 97% survivorship. The mean time to revision was 2.27 years. The most common failure mode was aseptic loosening (7/13). Fourteen reoperations were reported. Of all unrevised patients, 91% was either very satisfied or satisfied with their knee function. Robotic-arm-assisted medial UKA showed high survivorship and satisfaction at midterm follow-up in this prospective, multicenter study. However, in spite of the robotic technique, early fixation failure remains the primary cause for revision with cemented implants. Comparative studies are necessary to confirm these findings and compare to conventional implanted UKA and total knee arthroplasty.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0883-5403
1532-8406
DOI:10.1016/j.arth.2018.01.036