Optical Technologies for Endoscopic Real-Time Histologic Assessment of Colorectal Polyps: A Meta-Analysis

Accurate, real-time, endoscopic risk stratification of colorectal polyps would improve decision-making and optimize clinical efficiency. Technologies to manipulate endoscopic optical outputs can be used to predict polyp histology in vivo; however, it remains unclear how accuracy has progressed and w...

Full description

Saved in:
Bibliographic Details
Published inThe American journal of gastroenterology Vol. 114; no. 8; pp. 1219 - 1230
Main Authors Mason, Sam E, Poynter, Liam, Takats, Zoltan, Darzi, Ara, Kinross, James M
Format Journal Article
LanguageEnglish
Published United States 01.08.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Accurate, real-time, endoscopic risk stratification of colorectal polyps would improve decision-making and optimize clinical efficiency. Technologies to manipulate endoscopic optical outputs can be used to predict polyp histology in vivo; however, it remains unclear how accuracy has progressed and whether it is sufficient for routine clinical implementation. A meta-analysis was conducted by searching MEDLINE, Embase, and the Cochrane Library. Studies were included if they prospectively deployed an endoscopic optical technology for real-time in vivo prediction of adenomatous colorectal polyps. Polyposis and inflammatory bowel diseases were excluded. Bayesian bivariate meta-analysis was performed, presenting 95% confidence intervals (CI). One hundred two studies using optical technologies on 33,123 colorectal polyps were included. Digital chromoendoscopy differentiated neoplasia (adenoma and adenocarcinoma) from benign polyps with sensitivity of 92.2% (90.6%-93.9% CI) and specificity of 84.0% (81.5%-86.3% CI), with no difference between constituent technologies (narrow-band imaging, Fuji intelligent Chromo Endoscopy, iSCAN) or with only diminutive polyps. Dye chromoendoscopy had sensitivity of 92.7% (90.1%-94.9% CI) and specificity of 86.6% (82.9%-89.9% CI), similarly unchanged for diminutive polyps. Spectral analysis of autofluorescence had sensitivity of 94.4% (84.0%-99.1% CI) and specificity of 50.9% (13.2%-88.8% CI). Endomicroscopy had sensitivity of 93.6% (85.3%-98.3% CI) and specificity of 92.5% (81.8%-98.1% CI). Computer-aided diagnosis had sensitivity of 88.9% (74.2%-96.7% CI) and specificity of 80.4% (52.6%-95.7% CI). Prediction confidence and endoscopist experience alone did not significantly improve any technology. The only subgroup to demonstrate a negative predictive value for adenoma above 90% was digital chromoendoscopy, making high confidence predictions of diminutive recto-sigmoid polyps. Chronologic meta-analyses show a falling negative predictive value over time. A significant publication bias exists. This novel approach to meta-analysis demonstrates that existing optical technologies are increasingly unlikely to allow safe "resect and discard" strategies and that step-change innovation may be required. A "diagnose and leave" strategy may be supported for diminutive recto-sigmoid polyps diagnosed with high confidence; however, limitations exist in the evidence base for this cohort.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
ObjectType-Review-3
content type line 23
ISSN:0002-9270
1572-0241
DOI:10.14309/ajg.0000000000000156