Comparison of pre-oxygenation using spontaneous breathing through face mask and high-flow nasal oxygen: A randomised controlled crossover study in healthy volunteers

High-flow nasal oxygen (HFNO) therapy has been proposed for pre-oxygenation before intubation, but the end-tidal fraction of oxygen (ETO2) obtained remains unknown. To compare the ETO2 following a 3 min pre-oxygenation with HFNO and face mask. Operating room in a primary university hospital. A rando...

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of anaesthesiology Vol. 36; no. 5; p. 335
Main Authors Hanouz, Jean-Luc, Lhermitte, David, Gérard, Jean-Louis, Fischer, Marc Olivier
Format Journal Article
LanguageEnglish
Published England 01.05.2019
Online AccessGet more information

Cover

Loading…
More Information
Summary:High-flow nasal oxygen (HFNO) therapy has been proposed for pre-oxygenation before intubation, but the end-tidal fraction of oxygen (ETO2) obtained remains unknown. To compare the ETO2 following a 3 min pre-oxygenation with HFNO and face mask. Operating room in a primary university hospital. A randomised crossover study. Fifty healthy volunteers. Participants were randomly pre-oxygenated through spontaneous breathing 100% oxygen in a face mask and with HFNO (mouth closed, heated and humidified gas flow at 60 l min). In the face mask group, the ETO2 was measured continuously. In the HFNO group, the nasal cannula was quickly exchanged with a face mask while the subject held their breath at end inspiration and the ETO2 was measured after a deep expiration. The protocol ended when ETO2 reached 90% or otherwise at 6 min. The primary endpoint was the ETO2 after 3 min of pre-oxygenation. Secondary endpoints were the proportion of participants with an ETO2 at least 90% and the time until the ETO2 at least 90%. The ETO2 after 3 min of pre-oxygenation was 89 (2) % and 77 (12) % in the face mask and HFNO groups [difference 12% (95% confidence interval, 95% CI: 8 to 15]; P < 0.001), respectively. After 3 min of pre-oxygenation, 54 and 4% (P < 0.001) of volunteers had an ETO2 at least 90% in the face-mask and HFNO groups, respectively. After 6 min of pre-oxygenation, 96 and 46% (P < 0.001) of volunteers had an ETO2 at least 90% in the face-mask and HFNO groups, respectively. In the face mask group, the hazard ratio to achieve an ETO2 of 90% was 5.3 (95% CI: 3.2 to 8.9; P < 0.001). Our study demonstrates that pre-oxygenation with HFNO is not a reliable method of pre-oxygenation before the induction of anaesthesia. clinical trial NCT03399695.
ISSN:1365-2346
DOI:10.1097/EJA.0000000000000954