Intracavity pumped nanosecond optical parametric oscillator emitting in the eye-safe range
We report on a 1.57-mum wavelength singly resonant optical parametric oscillator (OPO) using a noncritically phase-matched KTP crystal intracavity pumped by an electro-optically Q-switched Nd:YAG laser. A simple model for numerical calculation of the temporal profile of the laser and signal pulses d...
Saved in:
Published in | Applied optics (2004) Vol. 40; no. 24; p. 4334 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
United States
20.08.2001
|
Online Access | Get more information |
Cover
Loading…
Summary: | We report on a 1.57-mum wavelength singly resonant optical parametric oscillator (OPO) using a noncritically phase-matched KTP crystal intracavity pumped by an electro-optically Q-switched Nd:YAG laser. A simple model for numerical calculation of the temporal profile of the laser and signal pulses developed inside the intracavity pumped OPO (IPOPO) resonator is described. Working conditions for single-pulse and multipulse parametric oscillation are established. A single signal pulse of 8.1-mJ output energy was obtained when the laser was pumped three times above the pulsed IPOPO threshold. A pulse duration of 5.9 ns was measured at 1.5 times above threshold for the IPOPO. |
---|---|
ISSN: | 1559-128X |
DOI: | 10.1364/ao.40.004334 |