Initial experience with intensity distribution analysis of hemodynamic parameters in the thoracic aorta using four-dimensional magnetic resonance imaging: A comparison between groups with different ejection fractions

The purpose of this study was to investigate whether there were significant differences in the intensity distributions of thoracic aorta hemodynamic parameters between groups with different ejection fractions (EF) using four-dimensional flow magnetic resonance imaging and to investigate the relation...

Full description

Saved in:
Bibliographic Details
Published inMedicine (Baltimore) Vol. 101; no. 2; p. e28563
Main Authors Nishimura, Takamasa, Sueyoshi, Eijun, Koike, Hirofumi, Uetani, Masataka
Format Journal Article
LanguageEnglish
Published United States Lippincott Williams & Wilkins 14.01.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The purpose of this study was to investigate whether there were significant differences in the intensity distributions of thoracic aorta hemodynamic parameters between groups with different ejection fractions (EF) using four-dimensional flow magnetic resonance imaging and to investigate the relationships between each parameter.A total of 26 patients, 13 each with EF of >60% and <30%, underwent cardiac four-dimensional flow magnetic resonance imaging (EF >60%: mean age: 54 ± 11.6 years, EF <30%: mean age: 49.2 ± 17.2 years). The thoracic aorta was divided into the proximal and distal ascending aorta (AAo), aortic arch, and the proximal and distal descending aorta, and each section was further divided into the anterior wall, posterior wall, lesser curvature, and greater curvature. The intensity distributions of wall shear stress (WSS), energy loss (EL), and vorticity (Vort) (hemodynamic parameters) and the concordance rates between these distributions were analyzed.The concordance rate between the intensity distributions of EL and Vort was high. Only the intensity distributions of EL and Vort in the distal AAo differed significantly between the groups (P < .001). In the EF >60% group, these intensity distributions showed higher values in the greater curvature of the AAo, whereas in the EF <30% group higher values were seen in the lesser curvature of the AAo.Although there was no significant intergroup difference in the WSS intensity distribution, in the EF <30% group the WSS intensity distribution tended to exhibit higher values in the lesser curvature of the distal AAo, and the WSS intensity distribution values for the greater curvature tended to gradually increase from the arch to the proximal descending aorta.The only significant differences between the EF groups were found in the intensity distributions of EL and Vort in the distal AAo. This suggests that the distributions of atherosclerosis may be EF-dependent.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0025-7974
1536-5964
DOI:10.1097/MD.0000000000028563