Endobronchial valve for treatment of persistent air leak complicating spontaneous pneumothorax

Endobronchial one-way valves have been proposed as treatment for persistent air leak complicating spontaneous pneumothorax in which surgical intervention is not feasible. However, published data on efficacy, safety, and factors associated with success are scanty. This is a retrospective study of 37...

Full description

Saved in:
Bibliographic Details
Published inHong Kong medical journal = Xianggang yi xue za zhi Vol. 24; no. 2; pp. 158 - 165
Main Authors Yu, W C, Yu, E Lm, Kwok, H C, She, H L, Kwong, K K, Chan, Y H, Tsang, Y L, Yeung, Y C
Format Journal Article
LanguageEnglish
Chinese
Published China Hong Kong Academy of Medicine 01.04.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Endobronchial one-way valves have been proposed as treatment for persistent air leak complicating spontaneous pneumothorax in which surgical intervention is not feasible. However, published data on efficacy, safety, and factors associated with success are scanty. This is a retrospective study of 37 patients at a general hospital from 2008 to 2016. The impact of endobronchial valve implantation on the time to air-leak cessation after bronchoscopy was evaluated. The median patient age was 71 years. The majority of patients were males (92%), were ever-smokers (83%), had at least one co-morbidity (97%), and had secondary spontaneous pneumothorax (89%). Nineteen patients (51%) had a mean of 2.6 endobronchial valves implanted (range, 1-6). The air leak ceased within 72 hours for only eight patients (22% of the complete cohort), with immediate air-leak cessation after completion of endobronchial valve implantation. All six successful cases that had computed tomographic data of the thorax were shown to have bilateral intact interlobar fissures. The median (interquartile range) Charlson co-morbidity index was 1 (0.25-1) and 2 (1-3) for the success group and failure group, respectively (P=0.029). All patients in the no-endobronchial valve group survived, whereas three patients in the endobronchial valve group died within 30 days of endobronchial valve implantation. Only a small proportion of cases of endobronchial valve implantation for air leak complicating pneumothorax had unequivocal success. Intact bilateral interlobar fissures appear to be a necessary, though not sufficient, condition for success. Patients with fewer medical co-morbidities and immediate air-leak cessation after endobronchial valve implantation have a higher likelihood of success.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1024-2708
2226-8707
DOI:10.12809/hkmj176823