Current 25-hydroxyvitamin D assays: Do they pass the test?

Vitamin D testing is becoming increasingly important with recent research demonstrating a correlation between vitamin D insufficiency and metabolic diseases, immunodeficiencies and other diseases. However, existing 25-hydroxyvitamin D (25OHD) assays lack comparability to the candidate reference meth...

Full description

Saved in:
Bibliographic Details
Published inClinica chimica acta Vol. 413; no. 13-14; pp. 1127 - 1134
Main Authors Ong, Lizhen, Saw, Sharon, Sahabdeen, Noorulhijjah Bte, Tey, Kiat Teng, Ho, Chung Shun, Sethi, Sunil Kumar
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 11.07.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Vitamin D testing is becoming increasingly important with recent research demonstrating a correlation between vitamin D insufficiency and metabolic diseases, immunodeficiencies and other diseases. However, existing 25-hydroxyvitamin D (25OHD) assays lack comparability to the candidate reference method, causing difficulties in diagnosis and monitoring of vitamin D deficiency. We looked at the accuracy of 3 automated assays (Roche Diagnostics Elecsys® Total 25OHD assay, Abbott Architect® Total vitamin D assay, Advia Centaur® vitamin D Total assay) and Diasorin® Radioimmunoassay (RIA) compared to a routine laboratory Liquid Chromatography–Tandem Mass Spectrometry (LC–MS/MS). The correlation based on Passing Bablok regression was good with the slopes between 0.95 and 1.31 and the intercepts between −3.24 and 3.68. However, a significant positive bias was observed using the Abbott Architect and the Diasorin RIA. Using published analytical goals of coefficient of variation (CV) <10% and bias <5%, most methods did not meet these criteria. Using measurement of uncertainty of 9%, most methods were able to meet criteria using quality control materials but not patient samples. Inadequacies of these assay performances are contributed by differences in method of extraction of vitamin D from vitamin D binding protein, cross-reactivities to 25OHD2, 25OHD3 and other vitamin D metabolites, matrix interferences and a lack of standardization. ► Five 25-hydroxyvitamin D (25OHD) assays were compared. ► Four 25OHD assays were evaluated using accuracy and precision data. ► The imprecision of quality control samples for the immunoassays was all below 10%. ► The imprecision of pooled serum samples for immunoassays was between 2.7% and 22.8%. ► Based on stringent analytical goals, most 25OHD assays did not meet the standards.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0009-8981
1873-3492