Improvement of the RF cavity for the SKKUCY-10 cyclotron
The SKKUCY-10 cyclotron based on 83.2 MHz, 40 kV half-wave RF cavity was developed at Sungkyunkwan University for the production of medical radioisotopes. The resonant frequency f RF of the cyclotron and the RF coupling coefficient β c of the RF cavity system were measured at various vacuum, and tem...
Saved in:
Published in | Journal of the Korean Physical Society Vol. 79; no. 9; pp. 857 - 863 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Seoul
The Korean Physical Society
01.11.2021
Springer Nature B.V 한국물리학회 |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The SKKUCY-10 cyclotron based on 83.2 MHz, 40 kV half-wave RF cavity was developed at Sungkyunkwan University for the production of medical radioisotopes. The resonant frequency
f
RF
of the cyclotron and the RF coupling coefficient
β
c
of the RF cavity system were measured at various vacuum, and temperature conditions. The normalized multi-pacting intensities at four positions in the power coupler were analyzed to predict the multi-pacting power. Differences,
Δ
f
RF
and
Δ
β
c
, caused by the vacuum, and temperature conditions were modified based on the coupler and tuner gap distances. During the RF conditioning, a constant 15 kW pulse mode and a variable 1 to 15 kW continuous wave mode were employed. The values of the reflection coefficient
Γ
and
β
c
were 1.2% and 0.8, respectively, when the cavity dissipation power was 12.4 kW at 83.2 MHz. Good agreement between the simulation and experimental data was obtained. |
---|---|