Scaffold thrombosis following implantation of the ABSORB BVS in routine clinical practice: Insight into possible mechanisms from optical coherence tomography

Objectives To identify potential underlying mechanisms of early and (very) late scaffold thrombosis (ScT) by optical coherence tomography (OCT), in a frame‐by‐frame analysis. Background The absorb scaffold is associated with an increased risk of ScT compared with metallic stents. Several potential c...

Full description

Saved in:
Bibliographic Details
Published inCatheterization and cardiovascular interventions Vol. 92; no. 2; pp. E106 - E114
Main Authors Kraak, Robin P., Kajita, Alexandre H., Garcia‐Garcia, Hector M., Henriques, Jose. P. S., Piek, Jan. J., Arkenbout, E. Karin, van der Schaaf, René J., Tijssen, Jan G. P., de Winter, Robbert J., Wykrzykowska, Joanna J.
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.08.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives To identify potential underlying mechanisms of early and (very) late scaffold thrombosis (ScT) by optical coherence tomography (OCT), in a frame‐by‐frame analysis. Background The absorb scaffold is associated with an increased risk of ScT compared with metallic stents. Several potential causes of bioresorbable ScT have been identified, however the precise etiology still remains unclear. Methods Between February 2013 and February 2016, 13 patients presenting with definite ScT underwent OCT imaging. After guidewire passage or balloon inflations, OCT images were acquired. Pullbacks were assessed offline at each 1 mm longitudinal interval within the treated segment and the 5 mm segments adjacent to both edges. Primary cause of ScT was assessed by reviewing medical records, baseline angiographic films, and OCT pullback and angiographic films at time of ScT. Results 13 patients, with 14 thrombotic lesions presented either with early ScT (i.e., ≤30 days) or very (late) (i.e., >30 days). Analysis demonstrated a significantly smaller in‐scaffold maximal lumen diameter in the early cases (2.75 ± 0.85 mm vs. 3.00 ± 0.46 mm; P = 0.033) and a nonsignificant smaller minimal scaffold diameter (2.44 ± 0.62 mm vs. 2.58 ± 0.37 mm P = 0.097). Per‐strut analysis demonstrated significantly more malapposed scaffold struts in (very) late cases (6% versus 0.6%, P < 0.001). Assessment of the predominate cause showed underexpansion as the dominant factor in the early cases, while malapposition was predominantly seen in the (very)late cases. Conclusions OCT performed in patients presenting with Absorb ScT demonstrated that malapposition of scaffold struts was more prominent in patients presenting with (very) late ScT, while underexpansion was more frequent in the early cases.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1522-1946
1522-726X