Role of maternal hyperoxygenation in predicting need for postnatal balloon atrial septostomy in fetal d‐transposition of the great arteries

ABSTRACT Objective Predicting whether postnatal balloon atrial septostomy (BAS) will be necessary for fetuses with dextro‐transposition of the great arteries (d‐TGA) remains challenging. We sought to determine whether fetal echocardiographic measurements obtained during maternal hyperoxygenation (MH...

Full description

Saved in:
Bibliographic Details
Published inUltrasound in obstetrics & gynecology Vol. 64; no. 5; pp. 589 - 596
Main Authors Szwast, A., Penney, C., Sharma, P., Rychik, J.
Format Journal Article
LanguageEnglish
Published Chichester, UK John Wiley & Sons, Ltd 01.11.2024
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:ABSTRACT Objective Predicting whether postnatal balloon atrial septostomy (BAS) will be necessary for fetuses with dextro‐transposition of the great arteries (d‐TGA) remains challenging. We sought to determine whether fetal echocardiographic measurements obtained during maternal hyperoxygenation (MH) can improve our ability to predict the need for postnatal BAS. Methods This was a retrospective, single‐institution review of d‐TGA fetuses whose mothers had undergone MH at 33–38 weeks' gestation at the Children's Hospital of Philadelphia, between 1 January 2017 and 30 March 2020. All fetal d‐TGA cases had either an intact ventricular septum or small ventricular septal defect measuring < 3 mm. Patent foramen ovale (PFO) size, measured by two‐dimensional imaging (2D) and by color Doppler, and patent ductus arteriosus (PDA) shunting (antegrade vs bidirectional) were assessed in room air (RA) and during MH. BAS status and timing were recorded. Results Of 41 fetal d‐TGA cases in the cohort, 23 underwent postnatal BAS, while 18 did not, and 14 subjects underwent emergent BAS within 3 h of delivery. On univariate analysis, PFO size measured both in RA and during MH and antegrade shunting in the PDA during MH predicted BAS. During MH, median PFO size by 2D was significantly smaller in fetuses which underwent emergent BAS compared to fetuses which did not undergo BAS (2.5 (interquartile range (IQR), 2.0–3.0) mm vs 4.1 (IQR, 3.4–5.0) mm; P < 0.001). On cut‐point analysis, PFO size by 2D during MH of ≤ 3.2 mm predicted the need for emergent BAS with a sensitivity of 93% (95% CI, 66–100%) and a specificity of 78% (95% CI, 58–91%). Conclusions In fetuses with d‐TGA, measurement of PFO size and direction of PDA shunting during MH improves our ability to predict the need for postnatal BAS, although additional study is needed. We propose incorporating third‐trimester MH when planning delivery of a d‐TGA fetus. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0960-7692
1469-0705
1469-0705
DOI:10.1002/uog.27664