Perception of point‐of‐care ultrasound performed by emergency medicine physicians

ABSTRACT Purpose Point‐of‐care ultrasound (POCUS) is integral to the practice of emergency medicine (EM). Furthermore, EM‐performed POCUS (EM‐POCUS) offers consultants the opportunity to avoid delays in care due to wait times for confirmatory imaging studies. This study is the first to describe the...

Full description

Saved in:
Bibliographic Details
Published inJournal of clinical ultrasound Vol. 45; no. 7; pp. 408 - 415
Main Authors Hansen, Whitney, Mitchell, Carl E., Bhattarai, Bikash, Ayutyanont, Napatkamon, Stowell, Jeffrey R.
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.09.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:ABSTRACT Purpose Point‐of‐care ultrasound (POCUS) is integral to the practice of emergency medicine (EM). Furthermore, EM‐performed POCUS (EM‐POCUS) offers consultants the opportunity to avoid delays in care due to wait times for confirmatory imaging studies. This study is the first to describe the perception of POCUS to consulting services at a single institution where EM‐POCUS is routinely performed. Methods This study was conducted as a survey distributed to residents from consultant specialties (internal medicine [IM], general surgery [GS], and obstetrics and gynecology [OB‐GYN]). Survey questions aimed to describe consultant's confidence and utilization of EM‐POCUS. Responses were evaluated using descriptive and comparative analysis. Results Survey responses were obtained from 27 IM (87.1%), 13 GS (100%), and 21 OB‐GYN (100%) respondents. Among consultant specialties, 47.5% of respondents reported comfort with EM‐POCUS. IM (81.5%) providers were significantly more likely to trust EM‐POCUS as compared with OB‐GYN (28.6%) and GS (7.7%) providers (p < 0.001). Confidence was further limited when consultants were unable to view POCUS images (23.8% for OB‐GYN, 15.4% for GS, 55.6% for IM), but improved with EM provider level of POCUS experience and training (81% for OB‐GYN, 76.9% for GS, 77.8% for IM). Overall, consultant utilization of EM‐POCUS was 68.9%. Conclusions Study respondents demonstrated limited confidence and utilization of EM‐POCUS in this institution. Increased understanding of EM‐POCUS training and expanded image availability may improve consultant utilization. Future studies, performed nationally, should further describe the value of EM‐POCUS to consultant services. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:408–415, 2017
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0091-2751
1097-0096
DOI:10.1002/jcu.22443