Evaluation of Pressure Drop and Particle Sphericity for an Air-rock Bed Thermal Energy Storage System

The pressure drop of a packed bed thermal energy storage system with irregular shaped solid pellets and tank-to-particle diameter ratio of 10.4 is investigated. The bed height to diameter ratio is 2. The particle sphericity is calculated and used to compare pressure drop correlations to the measured...

Full description

Saved in:
Bibliographic Details
Published inEnergy procedia Vol. 57; pp. 633 - 642
Main Authors Trahan, Jamie, Graziani, Alessandro, Goswami, D. Yogi, Stefanakos, E., Jotshi, Chand, Goel, Nitin
Format Journal Article
LanguageEnglish
Published Elsevier Ltd 2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The pressure drop of a packed bed thermal energy storage system with irregular shaped solid pellets and tank-to-particle diameter ratio of 10.4 is investigated. The bed height to diameter ratio is 2. The particle sphericity is calculated and used to compare pressure drop correlations to the measured values in the particle Reynolds number range of 353 ≤ Rep ≤ 5206.
ISSN:1876-6102
1876-6102
DOI:10.1016/j.egypro.2014.10.218