Higher-order polysulfides induced thermal runaway for 1.0 Ah lithium sulfur pouch cells

Comprehensive analyses on thermal runaway mechanisms are critically vital to achieve the safe lithium–sulfur (Li–S) batteries. The reactions between dissolved higher-order polysulfides and Li metal were found to be the origins for the thermal runaway of 1.0 Ah cycled Li–S pouch cells. 16-cycle pouch...

Full description

Saved in:
Bibliographic Details
Published inParticuology Vol. 79; pp. 10 - 17
Main Authors Jiang, Feng-Ni, Yang, Shi-Jie, Chen, Zi-Xian, Liu, He, Yuan, Hong, Liu, Lei, Huang, Jia-Qi, Cheng, Xin-Bing, Zhang, Qiang
Format Journal Article
LanguageEnglish
Published Elsevier B.V 01.08.2023
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Comprehensive analyses on thermal runaway mechanisms are critically vital to achieve the safe lithium–sulfur (Li–S) batteries. The reactions between dissolved higher-order polysulfides and Li metal were found to be the origins for the thermal runaway of 1.0 Ah cycled Li–S pouch cells. 16-cycle pouch cell indicates high safety, heating from 30 to 300 °C without thermal runaway, while 16-cycle pouch cell with additional electrolyte undergoes severe thermal runaway at 147.9 °C, demonstrating the key roles of the electrolyte on the thermal safety of batteries. On the contrary, thermal runaway does not occur for 45-cycle pouch cell despite the addition of the electrolyte. It is found that the higher-order polysulfides (Li2Sx ≥ 6) are discovered in 16-cycle electrolyte while the sulfur species in 45-cycle electrolyte are Li2Sx ≤ 4. In addition, strong exothermic reactions are discovered between cycled Li and dissolved higher-order polysulfide (Li2S6 and Li2S8) at 153.0 °C, driving the thermal runaway of cycled Li–S pouch cells. This work uncovers the potential safety risks of Li–S batteries and negative roles of the polysulfide shuttle for Li–S batteries from the safety view. [Display omitted] •The thermal safety of deeply cycled Li–S pouch cells have been systematically investigated.•Thermal behaviors of 16-cycle cells with/without electrolytes are due to different viscosities.•The thermal safety of 16/45-cycle cells depends on the polysulfides species in electrolytes.
ISSN:1674-2001
2210-4291
DOI:10.1016/j.partic.2022.11.009