Robotic-assisted total hip arthroplasty utilizing a fluoroscopy-guided system resulted in improved intra-operative efficiency relative to a computerized tomography-based platform

Robotic-assisted total hip arthroplasty (THA) using a computerized-tomography (CT) based workflow increases surgical time relative to traditional manual technique. The purpose of this investigation was to compare the intra-operative efficiencies of two robotic THA systems: a fluoroscopy-based platfo...

Full description

Saved in:
Bibliographic Details
Published inJournal of robotic surgery Vol. 17; no. 6; pp. 2841 - 2847
Main Authors Ong, Christian B., Buchan, Graham B. J., Hecht II, Christian J., Lawrie, Charles M., DeCook, Charles A., Sculco, Peter K., Kamath, Atul F.
Format Journal Article
LanguageEnglish
Published London Springer London 01.12.2023
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Robotic-assisted total hip arthroplasty (THA) using a computerized-tomography (CT) based workflow increases surgical time relative to traditional manual technique. The purpose of this investigation was to compare the intra-operative efficiencies of two robotic THA systems: a fluoroscopy-based platform (FL-RTHA) and a contemporary, CT-based (CT-RTHA) platform. A review of 107 consecutive FL-RTHA and 159 CT-RTHA primary, direct anterior approach (DAA) THA procedures was conducted. All cases were performed by one of two surgeons operating at the same institution, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included averages and consistencies (variances) for surgical times and operating room (OR) times. A secondary outcome was to quantify the duration of robot-active phases in the FL-RTHA workflow. The FL-RTHA cohort experienced shorter surgical times (38.71 min ± 7.00 vs. 75.33 min ± 11.38; p < 0.001) and OR times (101.35 min ± 12.22 vs. 156.74 min ± 17.79; p < 0.001) compared to the CT-RTHA cohort. Surgical times and OR times were both more consistent in the FL-RTHA cohort compared to the CT-RTHA cohort (p < 0.001). Patients who underwent DAA THA with the assistance of a fluoroscopy-based robotic system experienced shorter and more consistent surgical times and OR times compared to patients who underwent similar DAA THA procedures with a contemporary, CT-based robotic platform.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-3
content type line 23
ObjectType-Review-1
ISSN:1863-2491
1863-2483
1863-2491
DOI:10.1007/s11701-023-01723-7