Detection of Escherichia coli O157 using equal-length double-stranded fluorescence probe in a real-time polymerase chain reaction assay
Enterohemorrhagic Escherichia coli ( E. coli) O157 is a dangerous pathogen, which causes bloody diarrhea and severe hemolytic uremic syndrome (HUS). Although several assay systems based on real-time polymerase chain reaction (PCR) have been integrated to detect this pathogen, most of them are not sp...
Saved in:
Published in | Clinica chimica acta Vol. 366; no. 1; pp. 281 - 286 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
Netherlands
Elsevier B.V
01.04.2006
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Enterohemorrhagic
Escherichia coli (
E. coli) O157 is a dangerous pathogen, which causes bloody diarrhea and severe hemolytic uremic syndrome (HUS). Although several assay systems based on real-time polymerase chain reaction (PCR) have been integrated to detect this pathogen, most of them are not specific. We report a real-time quantitative PCR method targeting
rfbE, a gene specifically expressed in
E. coli O157. This method can therefore be used to diagnose enterohemorrhagic
Escherichia coli (
E. coli) O157.
A nucleic acid based diagnostic assay system, combining equal-length double-stranded fluorescence probe technique and real-time PCR, was developed to detect
E. coli O157. This assay system take advantage of the highly conserved
rfbE O-antigen synthesis gene, and a pair of fluorescence-quenching probes complementary to
rfbE gene were used in a real-time PCR to quantify the presence of the pathogen.
The specificity of the diagnostic method was assessed by comparing test results on 14 different related pathogens including common
E. coli, enteroinvasive
Escherichia coli (EIEC),
Salmonella,
Shigella and
E. coli O157. The detection limit of the method was determined using 10-fold serial dilutions of an
E. coli O157 standard sample, and as few as 1.49
×
10
3 CFU/ml could be detected. All
E. coli with serotype O157, which expresses
rfbE gene, were positive in this assay, while all other species without
rfbE gene expression were negative.
By combining equal-length double-stranded fluorescence probe technique and real-time PCR, we have developed a simple, rapid, specific and sensitive method to detect
E. coli O157. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0009-8981 1873-3492 |
DOI: | 10.1016/j.cca.2005.10.027 |