Finger Joint Angle Estimation Based on Motoneuron Discharge Activities

Estimation of joint kinematics plays an important role in intuitive human-machine interactions. However, continuous and reliable estimation of small (e.g., the finger) joint angles is still a challenge. The objective of this study was to continuously estimate finger joint angles using populational m...

Full description

Saved in:
Bibliographic Details
Published inIEEE journal of biomedical and health informatics Vol. 24; no. 3; pp. 760 - 767
Main Authors Dai, Chenyun, Hu, Xiaogang
Format Journal Article
LanguageEnglish
Published United States IEEE 01.03.2020
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Estimation of joint kinematics plays an important role in intuitive human-machine interactions. However, continuous and reliable estimation of small (e.g., the finger) joint angles is still a challenge. The objective of this study was to continuously estimate finger joint angles using populational motoneuron firing activities. Multi-channel surface electromyogram (sEMG) signals were obtained from the extensor digitorum communis muscles, while the subjects performed individual finger oscillatory extension movements at two different speeds. The individual finger movement was first classified based on the EMG signals. The discharge timings of individual motor units were extracted through high-density EMG decomposition, and were then pooled as a composite discharge train. The firing frequency of the populational motor unit firing events was used to represent the descending neural drive to the motor unit pool. A second-order polynomial regression was then performed to predict the measured metacarpophalangeal extension angle using the derived neural drive based on the neuronal firings. Our results showed that individual finger extension movement can be classified with >96% accuracy based on multi-channel EMG. The extension angles of individual fingers can be predicted continuously by the derived neural drive with R 2 values >0.8. The performance of the neural-drive-based approach was superior to the conventional EMG-amplitude-based approach, especially during fast movements. These findings indicated that the neural-drive-based interface was a promising approach to reliably predict individual finger kinematics.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:2168-2194
2168-2208
2168-2208
DOI:10.1109/JBHI.2019.2926307