Force Closure Mechanism Modeling for Musculoskeletal Multibody Simulation

Objective: Neuro-musculoskeletal multibody simulation (NMBS) seeks to optimize decision-making for patients with neuro-musculoskeletal disorders. In clinical practice, however, the inter-subject variability and the inaccessibility for experimental testing impede the reliable model identification. Th...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on biomedical engineering Vol. 65; no. 11; pp. 2471 - 2482
Main Authors Geier, Andreas, Aschemann, Harald, D'Lima, Darryl, Woernle, Christoph, Bader, Rainer
Format Journal Article
LanguageEnglish
Published United States IEEE 01.11.2018
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective: Neuro-musculoskeletal multibody simulation (NMBS) seeks to optimize decision-making for patients with neuro-musculoskeletal disorders. In clinical practice, however, the inter-subject variability and the inaccessibility for experimental testing impede the reliable model identification. These limitations motivate the novel modeling approach termed as force closure mechanism modeling (FCM 2 ). Methods: FCM 2 expresses the dynamics between mutually articulating joint partners with respect to instantaneous screw axes (ISA) automatically reconstructed from their relative velocity state. Thereby, FCM 2 reduces arbitrary open-chain multibody topologies to force closure n-link pendulums. Within a computational validation study on the human knee joint with implemented contact surfaces, we examine FCM 2 as an underlying inverse dynamic model for computed muscle control. We evaluate predicted tibiofemoral joint quantities, i.e., kinematics and contact forces along with muscle moment arms, during muscle-induced knee motion against the classic hinge joint model and experimental studies. Results: Our NMBS study provided the proof-of-principle of the novel modeling approach. FCM 2 freed us from assuming a certain joint formulation while correctly predicting the joint dynamics in agreement with the established methods. Although experimental results were closely predicted, owing to noise in the ISA estimation, muscle moment arms were overestimated (RISA = 0.84 <; RHINGE = 0.97, RMSEISA = 13.18 mm > RMSEHINGE = 6.54 mm), identifying the robust ISA estimation as key to FCM 2 . Conclusion: FCM 2 automatically derives the equations of motion in closed form. Moreover, it captures subject-specific joint function and, thereby, minimizes modeling and parameterization efforts. Significance: Model derivation becomes driven by quantitative data available in clinical settings so that FCM 2 yields a promising framework toward subject-specific NMBS.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0018-9294
1558-2531
1558-2531
DOI:10.1109/TBME.2018.2800293